WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity before servicing. Check appliance is safe when you have finished.
22
8. Servicing
Disconnect the cooker from the electricity supply
before servicing, particularly before removing any
of the following: control panel, side panels, ceramic
hob, or any of the electrical components or cover
boxes.
Before reconnection, check that the appliance is
electrically safe.
1.
To Remove a Side Panel
Disconnect from electricity supply.
Pull the cooker forward. Pull off the control panel end caps
at each end of the panel
(Fig.8-1)
. Remove the fixing screws
under the end caps.
Remove the retaining screws for each panel (one at the front,
two at the rear, and one at each lower front corner of the side
panels).
Reassemble in reverse order.
2.
To Lift up the Ceramic Hob
Disconnect from electricity supply.
Pull the cooker forwards. Unscrew the two screws located at
the rear on the either side of the cooker.
Remove the side panels (see 1) to allow access to the hob
fixing screws (1 each side) at the top of the side uprights.
Remove these screws.
Lift up the ceramic hob at the front and prop in position with a
non-metallic prop.
CAUTION:
The ceramic hob material is much more sensitive
to scratches on the underside than the top.
Take care not to touch or scratch the underside of the ceramic
as this will weaken the material and cause the top to shatter.
3.
To Remove the Control Panel
Disconnect from electricity supply.
Lift up the front of the ceramic hob (see 2). Remove the
control panel top screws. Pull off all the control knobs.
Open the grill and right-hand oven door and remove the
fixing screws underneath the control panel. The screws
directly below the clock are for the clock fixing bracket, so do
not remove them at this stage.
Lift the control panel, pull forward and disconnect the wiring
from the rear.
Reassemble in reverse order. When replacing leads, refer to
the wiring diagram in this manual. Check the operation of the
timer.
4.
To Replace a Hob Element
Disconnect from electricity supply.
Lift up the ceramic hob (see 2). The Induction Heating
Elements (IHE) are now accessible. Note the wire connection
positions and element orientation for re-assembly. Disconnect
the wires, and remove the element unit and springs. Re-
assemble in the reverse order.
Note:
The IHE will require commissioning when the hob has
been refitted.
ArtNo.210-0008 - Classic
Removing the end caps
Fig.8-1