Recirculation Version Air Outlet 

To install the Recirculation Version of the hood, the Activated 

charcoal filter must be fitted, see paragraph “ Activated charcoal 

filter (Recirculation version)”. 
•  Screw the filter cover onto the air outlet, using four screws 

12c

(2.9 x 12.5). 

•  Fix the directional grille 

8

 on the recirculation air outlet using 

the 2 screws 

12d

 (2,9 x 9,5) provided.

16

12c

12d

8

ELECTRICAL CONNECTION 

•  Connect the hood to the mains through a two-pole switch hav-

ing a contact gap of at least 3 mm. 

•  Remove the grease filters (see paragraph Maintenance) being 

sure  that  the  connector  of  the  feeding  cable  is  correctly  in-

serted in the socket placed on the side of the fan. 

Flue assembly 

The chimney can only be installed with exhausting hood 
•  Fasten the angle iron 

15

 to the hood canopy using the screws 

12d

(2,9 x 9,5)  provided. 

Upper exhaust flue

•  Slightly widen the two sides of the upper flue and hook them 

behind  the  brackets 

7.2.1

,  making  sure  that  they  are  well 

seated. 

•  Secure the sides to the brackets using the 4 screws 

12c

 (2,9 x 

6,5) supplied. 

Lower exhaust flue

•  Slightly  widen  the  two  sides  of  the  flue  and  hook  them  be-

tween the upper flue and the wall, making sure that they are 

well seated. 

•  Fix the lower part laterally to the hood body using the 2 screws 

12c

 (2,9 x 6,5) supplied.

Summary of Contents for OPLHD60

Page 1: ...OPLHD60 OPLHD90 OPLHD100 OPAL HOOD Instructions Manual www rangemaster co uk...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 5 USE 8 MAINTENANCE 9 EN...

Page 3: ...lationforthegashobspecifyagreaterdistancespecifiedabove thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled USE Theextractorhoodhasbeendesignedexclusivelyfordomesticus...

Page 4: ...2 2 1 Lower Section 8 1 Directional Air Outlet grille 9 1 Reducer Flange 150 120 mm 10 1 Adapting ring 120 125 mm 15 1 Angle iron 16 1 Filter cover Ref Q ty Installation Components 7 2 1 2 Upper Chim...

Page 5: ...other side checking that the two marks are levelled Drill at the marked points 1 using a 12 mm drill bit Drill at the marked points 2 using a 8 mm drill bit Insert the bracket plugs 11a into the holes...

Page 6: ...sten the safety screw 12a Close the doors the door again 12a Vr 11a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using either a flex...

Page 7: ...ph Maintenance being sure that the connector of the feeding cable is correctly in serted in the socket placed on the side of the fan Flue assembly The chimney can only be installed with exhausting hoo...

Page 8: ...le to change the op erating speed when this function is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 secon...

Page 9: ...y for particularly heavy usage and can be washed in a dishwasher Pull the comfort panels to open them Remove the filters one by one pushing them towards the back side of the hood unit and simultaneous...

Page 10: ...metal grease filters Remove the saturated activated charcoal filter as shown A Fit the new filters B Replace the metal grease filters Close the comfort panels A B Lighting unit Warning This appliance...

Page 11: ......

Page 12: ...991 0301 958_ver4 AGA RANGEMASTER GROUP PLC...

Reviews: