background image

EN

5

5

INSTALLATION

Wall drilling and bracket fixing 

11a

1

1

2

2

140

11

12a

164 164

788

540

450

140

X

1÷2

7.2.1

As a first step, proceed with the following drawings: 

•  a vertical line up to the ceiling or up to the upper limit, at the centre of

 the area in which the 

hood is to be fitted; 

•  a horizontal line at a minimum  788 mm above the cooker top.  

•  Mark a point 

(1)

 on the horizontal line, 164 mm to the right of the vertical reference line.  

•  Repeat this operation on the other side, checking that the two marks are levelled. 

•  Mark a reference point 

(2)

 as indicated at 140 mm from the vertical reference line and 540 

mm above the cooker top. 

•  Repeat this operation on the other side, checking that the two marks are levelled. 

•  Drill at the marked points 

(1)

, using a ø 12 mm drill bit. 

•  Drill at the marked points 

(2)

 using a ø 8 mm drill bit.  

•  Insert the bracket plugs 

11a

 into the holes (

1)

 and tighten the screws. 

•  Insert plug 

11

 into holes 

(2)

.

To install a decorative chimney ( optional )

•  Place  bracket 

7.2.1

  on  the  wall,  about  1-2  mm  from  the  ceiling  or  from  the  upper  limit, 

aligning the centre (notch) with the vertical reference line.  

•  Mark the wall at the centres of the bracket holes. 

•  Place the bracket 

7.2.1

 on the wall at X mm below the first bracket (X = height of the upper 

chimney section), aligning the centre (notch) with the vertical line. 

•  Mark the wall at the centres of the bracket holes. 

•  Drill ø 8 mm holes at all the marked centre points. 

•  Insert the wall plugs 

11

 in the holes. 

•  Fix the brackets using the 

12a

 screws (4,2 x 44,4) supplied with the hood. 

Summary of Contents for OPLHD60

Page 1: ...OPLHD60 OPLHD90 OPLHD100 OPAL HOOD Instructions Manual www rangemaster co uk...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 5 USE 8 MAINTENANCE 9 EN...

Page 3: ...lationforthegashobspecifyagreaterdistancespecifiedabove thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled USE Theextractorhoodhasbeendesignedexclusivelyfordomesticus...

Page 4: ...2 2 1 Lower Section 8 1 Directional Air Outlet grille 9 1 Reducer Flange 150 120 mm 10 1 Adapting ring 120 125 mm 15 1 Angle iron 16 1 Filter cover Ref Q ty Installation Components 7 2 1 2 Upper Chim...

Page 5: ...other side checking that the two marks are levelled Drill at the marked points 1 using a 12 mm drill bit Drill at the marked points 2 using a 8 mm drill bit Insert the bracket plugs 11a into the holes...

Page 6: ...sten the safety screw 12a Close the doors the door again 12a Vr 11a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using either a flex...

Page 7: ...ph Maintenance being sure that the connector of the feeding cable is correctly in serted in the socket placed on the side of the fan Flue assembly The chimney can only be installed with exhausting hoo...

Page 8: ...le to change the op erating speed when this function is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 secon...

Page 9: ...y for particularly heavy usage and can be washed in a dishwasher Pull the comfort panels to open them Remove the filters one by one pushing them towards the back side of the hood unit and simultaneous...

Page 10: ...metal grease filters Remove the saturated activated charcoal filter as shown A Fit the new filters B Replace the metal grease filters Close the comfort panels A B Lighting unit Warning This appliance...

Page 11: ......

Page 12: ...991 0301 958_ver4 AGA RANGEMASTER GROUP PLC...