background image

 

 

 

 

 

EN 

6

 

Fitting the hood body 

•  Open the doors/the door (See section Open Panels). 
•  Remove the Metal grease filters using the handles 

provided. 

•  Adjust the two screws 

Vr

, in the brackets 

11a,

 so that 

they are at the start of their travel.  

•  Hook the hood body to the two brackets 

11a

•  From the inside of the hood body, turn screws 

Vr

 to 

level the hood body itself. 

•  Fasten the safety screw 

12a

•  Close the doors/the door again. 
 

 

 

 

12a

Vr

11a

Connections 

DUCTED VERSION AIR EXHAUST SYSTEM 

When installing the ducted version, connect the hood to 
the chimney using either a flexible or rigid pipe ø 150 
or 125 mm, the choice of which is left to the installer. 
 
•  To install a ø 125 mm air exhaust connection, insert 

the reducer flange 

9

 on the hood body air outlet and 

the adapting ring ø120-125 

10

 on the reducer flange. 

•  Fix the pipe in position using sufficient pipe clamps 

(not supplied). 

•  Remove any activated charcoal filters.

 

 

9

ø 125

10

ø 150

Summary of Contents for OPLHD60

Page 1: ...OPLHD60 OPLHD90 OPLHD100 OPAL HOOD Instructions Manual www rangemaster co uk...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 5 USE 8 MAINTENANCE 9 EN...

Page 3: ...lationforthegashobspecifyagreaterdistancespecifiedabove thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled USE Theextractorhoodhasbeendesignedexclusivelyfordomesticus...

Page 4: ...2 2 1 Lower Section 8 1 Directional Air Outlet grille 9 1 Reducer Flange 150 120 mm 10 1 Adapting ring 120 125 mm 15 1 Angle iron 16 1 Filter cover Ref Q ty Installation Components 7 2 1 2 Upper Chim...

Page 5: ...other side checking that the two marks are levelled Drill at the marked points 1 using a 12 mm drill bit Drill at the marked points 2 using a 8 mm drill bit Insert the bracket plugs 11a into the holes...

Page 6: ...sten the safety screw 12a Close the doors the door again 12a Vr 11a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using either a flex...

Page 7: ...ph Maintenance being sure that the connector of the feeding cable is correctly in serted in the socket placed on the side of the fan Flue assembly The chimney can only be installed with exhausting hoo...

Page 8: ...le to change the op erating speed when this function is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 secon...

Page 9: ...y for particularly heavy usage and can be washed in a dishwasher Pull the comfort panels to open them Remove the filters one by one pushing them towards the back side of the hood unit and simultaneous...

Page 10: ...metal grease filters Remove the saturated activated charcoal filter as shown A Fit the new filters B Replace the metal grease filters Close the comfort panels A B Lighting unit Warning This appliance...

Page 11: ......

Page 12: ...991 0301 958_ver4 AGA RANGEMASTER GROUP PLC...