AIR OUTLET – RECIRCULATION VERSION 

• Unfasten the 2 screws fixing the upper bracket 

7.2.1

.

• Fasten the air outlet connector 

15 

in its place, using the 2

screws removed as above.

• Join the Connector 

15

 to the Hood canopy outlet using a

rigid or flexible pipe ø150 mm, selection of which is at
the discretion of the installation technician.

• Make sure that the Activated charcoal odour filter has

been fitted.

ELECTRICAL CONNECTION 

• Connect the hood to the mains through a two-pole switch

having a contact gap of at least 3 mm.

• Remove the grease filters (see paragraph Maintenance)

being sure that the connector of the feeding cable is cor-
rectly inserted in the socket placed on the side of the fan.

Flue assembly 

Upper exhaust flue

 

• Slightly widen the two sides of the upper flue and hook

them behind the brackets 

7.2.1

, making sure that they are

well seated.

• Secure the sides to the brackets by using the 4 screws 

12c

(2,9 x 9,5) supplied.

• Make sure that the outlet of the extensions pieces is

aligned with the chimney outlets.

Lower exhaust flue

 

• Slightly widen the two sides of the flue and hook them

between the upper flue and the wall,  making sure that
they are well seated.

• Fix the lower part laterally to the hood body by using the

2 screws 

12c

 (2,9 x 9,5) supplied.

12b

Summary of Contents for INFHDS90SS

Page 1: ...www rangemaster co uk INFHDS90SS INFHDS90BL INFHDS90SL INFHDS100SS INFHDS100BL INFHDS100SL INFHDS110SS INFHDS110BL INFHDS110SL COOKER HOOD EN...

Page 2: ...2 2 INDEX SAFETY INFORMATION 3 CHARACTERISTICS 6 INSTALLATION 7 USE 10 CARE AND CLEANING 11 EN...

Page 3: ...height please refer to the paragraphs on working dimensions and installation If the instructions for installation of the gas hob specify a greater distance this must be respected Check that the mains...

Page 4: ...to be adopted for fume discharging it is important to closely follow the regulations pro vided by the local authorities WARNING Before installing the Hood remove the protective films Use only screws a...

Page 5: ...ls not applicable to appliances that only discharge the air back into the room The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead i...

Page 6: ...ters 2 1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 1 Hood Body Fixing Brackets...

Page 7: ...t 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes i...

Page 8: ...body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove possible charcoal filters 9 120 150 Exhausted mode Recommendations and suggestions Connect the extractor to the e...

Page 9: ...e grease filters see paragraph Maintenance being sure that the connector of the feeding cable is cor rectly inserted in the socket placed on the side of the fan Flue assembly Upper exhaust flue Slight...

Page 10: ...recirculation mode Turn the Motor on at speed three Reset alarm grease and charcoal filter saturation C Speed Pres and hold the button for approximately 2 seconds with all the loads turned off Motor...

Page 11: ...ng When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and...

Page 12: ...991 0588 933_ver2 190708 D00005916_01 AGA RANGEMASTER GROUP PLC...

Reviews: