Mounting the hood body 

Installation with Bracket 

• Hook the hood body onto the bracket 

7.1

 installed.

• Fix definitively the Hood body onto the bracket by 2 Screws

12t

.

Connections 

DUCTED VERSION AIR EXHAUST SYSTEM 

When installing the ducted version, connect the hood to the 
chimney using either a flexible or rigid pipe ø 150 or 120 mm, 
the choice of which is left to the installer. 
• To install a ø 120 mm air exhaust connection, insert the re-

ducer flange 

9

 on the hood body outlet.

• Fix the pipe in position using sufficient pipe clamps (not sup-

plied).

• Remove possible charcoal filters.

9

ø 120

ø 150

Exhausted mode Recommendations and suggestions 

Connect the extractor to the exhaust flue through a pipe of minimum diameter 125 mm. 
The route of the flue must be as short as possible. 
Ideal ducting distance to discharge outlet is maximum of 3 meters straight run, or 2 meters and one 90 de-
gree bend preferably rigid duct. 

Maximum ducting distance should be 3 meters, with one 90 degree bend. 
For each additional 90 degree bend, the maximum distance is reduced by 1 meter. 
If the ducting is not correct it will increase noise and reduce performance. 

Summary of Contents for INFHDS90SS

Page 1: ...www rangemaster co uk INFHDS90SS INFHDS90BL INFHDS90SL INFHDS100SS INFHDS100BL INFHDS100SL INFHDS110SS INFHDS110BL INFHDS110SL COOKER HOOD EN...

Page 2: ...2 2 INDEX SAFETY INFORMATION 3 CHARACTERISTICS 6 INSTALLATION 7 USE 10 CARE AND CLEANING 11 EN...

Page 3: ...height please refer to the paragraphs on working dimensions and installation If the instructions for installation of the gas hob specify a greater distance this must be respected Check that the mains...

Page 4: ...to be adopted for fume discharging it is important to closely follow the regulations pro vided by the local authorities WARNING Before installing the Hood remove the protective films Use only screws a...

Page 5: ...ls not applicable to appliances that only discharge the air back into the room The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead i...

Page 6: ...ters 2 1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 1 Hood Body Fixing Brackets...

Page 7: ...t 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes i...

Page 8: ...body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove possible charcoal filters 9 120 150 Exhausted mode Recommendations and suggestions Connect the extractor to the e...

Page 9: ...e grease filters see paragraph Maintenance being sure that the connector of the feeding cable is cor rectly inserted in the socket placed on the side of the fan Flue assembly Upper exhaust flue Slight...

Page 10: ...recirculation mode Turn the Motor on at speed three Reset alarm grease and charcoal filter saturation C Speed Pres and hold the button for approximately 2 seconds with all the loads turned off Motor...

Page 11: ...ng When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and...

Page 12: ...991 0588 933_ver2 190708 D00005916_01 AGA RANGEMASTER GROUP PLC...

Reviews: