If the extractor is used in conjunction with non-electrical appliances 
(e.g. gas burning appliances), a sufficient degree of aeration must be 
guaranteed in the room in order to prevent the backflow of exhaust gas. 
When the cooker hood is used in conjunction with appliances supplied 
with energy other than electric, the negative pressure in the room must 
not exceed 0,04 mbar to prevent fumes being drawn back into the room 
by the cooker hood. 



The air must not be discharged into a flue that is used for exhausting 
fumes from appliances burning gas or other fuels. 



If the supply cord is damaged, it must be replaced from the manufac-
turer or its service agent. 



Connect the plug to a socket complying with current regulations, lo-
cated in an accessible place. 



With regards to the technical and safety measures to be adopted for 
fume discharging it is important to closely follow the regulations pro-
vided by the local authorities. 

 WARNING: Before installing the Hood, remove the protective films. 



Use only screws and small parts 

supplied with

 the hood. 

 WARNING: Failure to install the screws or fixing device in accordance 

with these instructions may result in electrical hazards. 



Do not look directly at the light through optical devices (binoculars, 
magnifying glasses…). 



Do not flambè under the range hood; risk of fire. 



This appliance can be used by children aged from 8 years and above 
and persons with reduced physical, sensory or mental capabilities or 
lack of experience and knowledge if they have been given supervision 
or instruction concerning use of the appliance in a safe way and under-
stand the hazards involved. Children shall not play with the appliance. 
Cleaning and user maintenance shall not be made by children without 
supervision. 



Children should be supervised to ensure that they do not play with the 
appliance. 

 

Summary of Contents for INFHDS90SS

Page 1: ...www rangemaster co uk INFHDS90SS INFHDS90BL INFHDS90SL INFHDS100SS INFHDS100BL INFHDS100SL INFHDS110SS INFHDS110BL INFHDS110SL COOKER HOOD EN...

Page 2: ...2 2 INDEX SAFETY INFORMATION 3 CHARACTERISTICS 6 INSTALLATION 7 USE 10 CARE AND CLEANING 11 EN...

Page 3: ...height please refer to the paragraphs on working dimensions and installation If the instructions for installation of the gas hob specify a greater distance this must be respected Check that the mains...

Page 4: ...to be adopted for fume discharging it is important to closely follow the regulations pro vided by the local authorities WARNING Before installing the Hood remove the protective films Use only screws a...

Page 5: ...ls not applicable to appliances that only discharge the air back into the room The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead i...

Page 6: ...ters 2 1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 1 Hood Body Fixing Brackets...

Page 7: ...t 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes i...

Page 8: ...body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove possible charcoal filters 9 120 150 Exhausted mode Recommendations and suggestions Connect the extractor to the e...

Page 9: ...e grease filters see paragraph Maintenance being sure that the connector of the feeding cable is cor rectly inserted in the socket placed on the side of the fan Flue assembly Upper exhaust flue Slight...

Page 10: ...recirculation mode Turn the Motor on at speed three Reset alarm grease and charcoal filter saturation C Speed Pres and hold the button for approximately 2 seconds with all the loads turned off Motor...

Page 11: ...ng When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and...

Page 12: ...991 0588 933_ver2 190708 D00005916_01 AGA RANGEMASTER GROUP PLC...

Reviews: