35
WARNING SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Pressure Testing
Connect the appliance to the gas supply. Check the
appliance is gas sound.
The gas pressure can be measured at one of the left
hand hotplate burner jets. Lift off a burner head. Fit the
pressure gauge to the jet. Turn on the hotplate burner
and turn on and light one of the other burners.
The pressure should be 29mbar for Butane and 37mbar
for Propane. After checking the pressure, turn the taps
off and replace the burner head.
Reassemble burner top, making sure it is reassembled in
the correct way on the burner body.
Check the appliance is gas sound.
Check operation of all the burners.
Natural Gas
L.P. Gas
Hotplate
Injector
Bypass screw Injector
Bypass screw
Right hand Wok burner
internal 80
96
internal 54
57
external 129
external 77
Large Burners
134
54
87
40
Medium Burners
109
39
68
32
Small Burner
75
38
51
28
Summary of Contents for Excel FSD
Page 1: ...Excel FSD 110 Dual Fuel Users Guide Installation Service Instructions U109010 02...
Page 43: ...43...
Page 44: ...220506...