36
INSTALLATION
Check the appliance is electrically safe when you have finished.
Electrical Connection
This appliance must be installed by a qualified electrician
to comply with the relevant Institution of Engineering and
Technology (I.E.T.) regulations and also the local electricity
supply company requirements.
n
n
Before connecting your appliance, ensure that
the information on the data plate (voltage and
connected load) matches that of the mains
electricity supply. If in doubt, consult a qualified
electrician.
n
n
Safety cut out devices must be included in the mains
power supply in compliance with the installation
regulations in the country concerned.
n
n
WARNING: THIS APPLIANCE MUST BE EARTHED
n
n
DO NOT use multiple sockets or extensions.
n
n
The power cable must be long enough to allow the
appliance to be extracted from the cabinet to fill the
coffee beans container.
This appliance must be connected by a competent person,
using fixed wiring via a double pole switched fused spur
outlet, protected by a 13A fuse (Fig. 6.2).
We recommend that the appliance is connected by a
qualified electrician, who is a member of the N.I.C.E.I.C. and
who will comply with the I.E.T. and local regulations. The
wires in the mains lead are coloured in accordance with the
following code:
n
n
This appliance must be fitted to a double pole 13A
fused switch socket.
n
n
This appliance MUST NOT be fitted with a plug and
connected to standard wall plug.
The mains terminal is situated on the back of the appliance.
• GREEN AND YELLOW = EARTH
• BLUE = NEUTRAL
• BROWN = LIVE.
Ensure the cable route avoids the risk of trapping or touching
hot surfaces.
Current Operated Earth Leakage
Breakers
Where the installation is protected by a 30mA sensitivity
residual current device (RCD), the combined use of your
appliance and other domestic appliances may occasionally
cause nuisance tripping. In these instances the kitchen circuit
may need to be reconfigured. This work should be carried out
by a qualified electrician.
DOUBLE POLE SWITCHED
FUSE SPUR OUTLET
13A
FUSE
ON
Fig. 6.2