28
10. Technical Data
This cooker is designed for use on either:
•
Natural gas (Cat I2H) at 20 mbar or
•
LP gas (Cat I3+) Butane 29 mbar / Propane 37 mbar
INSTALLER:
Please leave these instructions with the user.
DATA BADGE LOCATION:
Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION:
GB, IE.
Connections
See the appliance badge for test pressures.
Gas (Rp ½ at rear right-hand side)
Electric
Natural gas
20 mbar
230 / 400 V 50 Hz
Butane
29 mbar
Propane
37 mbar
Dimensions
Overall height
minimum 895 mm
maximum 925 mm
Overall width
600 mm
Overall depth
600 mm (to fascia inc. splashback); 610 mm (over hotplate)
Minimum space above hotplate
700 mm / 650 mm with cooker hood
Refer to 'Positioning the Cooker'.
Ratings
Hotplate
Natural Gas 20 mb
L.P. Gas
Injector
Injector
Rapid burner
2.9 kW
115
3 kW (218.1g/h)
85
Medium burner
1.75 kW
97
1.75 kW (127.2 g/h)
65
Small burner
1.0 kW
72
1.0 kW (72.7 g/h)
50
Main oven
2.4 kW
115
2.4 kW (174.5 g/h)
75
Top oven
2.4 kW
115
2.4 kW (174.5 g/h)
75
Consumption is based on G30.