background image

3

1) BURNERS

The diagram on the front panel next to each knob
shows which burner it controls. To light a burner
make sure that the gas is turned on and then:

- Automatic electrical ignition

Push and turn the knob corresponding to the
required burner in an anticlockwise direction until it
reaches the full on position (large flame fig. 1), then
depress the knob.

HOW TO USE THE BURNERS 

To achieve maximum efficiency with the least
possible gas consumption:
- Use the right size pan for each burner (consult the

following table and fig. 2).

- When the pan comes to the boil, set the knob to

the reduced rate position (small flame fig. 1). 

- Always place a lid on the pans. 

Burners

Power ratings

Pans Ø in cm

Ultra rapid

3100

24 - 26

Rapid

2800

20 - 22

Semirapid

1750

16 - 18

Auxiliary

1000

10 - 14

WARNINGS:
- Never leave the appliance unattended when

the burners are being used. Make sure there
are no children in the near vicinity.
Particularly make sure that the pan handles
are correctly positioned and keep a check on
foods requiring oil and grease to cook since
these products can easily catch fire.

- Never use aerosols near the appliance when

it is operating.

- If the built-in hotplate has a lid, any spilt

food should be immediately removed from
this before it is opened. If the appliance has
a glass lid, this could shatter when the
hotplate becomes hot. Always switch off all
the burners before closing the lid.

USE

FIG. 2

FIG. 1

Summary of Contents for 58580

Page 1: ...Cooker hood or appliance name Users Guide Installation Instructions Instruction Number www rangemaster co uk COD 01063GB 30 05 2002...

Page 2: ...ed steel pan support 6 Central enamelled steel pan support for ultra rapid burner 7 Burner n 1 control knob 8 Burner n 2 control knob 9 Burner n 3 control knob 10 Burner n 4 control knob 11 Electric i...

Page 3: ...on small flame fig 1 Always place a lid on the pans Burners Power ratings Pans in cm Ultra rapid 3100 24 26 Rapid 2800 20 22 Semirapid 1750 16 18 Auxiliary 1000 10 14 WARNINGS Never leave the applianc...

Page 4: ...ural air vents clear fig 3 and by activating the mechanical aeration device suction hood or electric fan fig 4 and fig 5 Intensive and lengthy use of the appliance may require additional ventilation T...

Page 5: ...use abrasive powders Do not allow vinegar coffee milk salted water lemon or tomato juice to remain in contact with the enamelled surfaces for long periods of time WARNINGS Before refitting the burner...

Page 6: ...with the installation dimensions see fig 7 8 The appliance is class 3 and should therefore installed built in as detailed in these instructions 4 FIXING THE HOTPLATE The hotplate has a special seal th...

Page 7: ...r vent of effective area 50cm2 is required while if the volume exceeds 11m3 no air vent is required However if the room has a door that opens directly to the outside no air vent is required even when...

Page 8: ...No part of the pipe must be able to touch parts the temperature of which exceeds 75 C The pipe must not be pulled or twisted throttled or tightly bent It must not come into contact with sharp edges or...

Page 9: ...erature rise of 50 C in any part Never use adaptors or inline connectors since these could cause false contacts and dangerous overheating When the appliance is connected straight to the electricity ma...

Page 10: ...ight the burner and turn to the Reduced rate position small flame fig 1 Pull off the control knob M fig 12 Insert a small screwdriver D into the hole C fig 12 and turn the throttle screw to the right...

Page 11: ...diameter of the injectors and the working pressures of the various types of gas CONVERSIONS BURNER ARRANGEMENT ON THE HOTPLATE BUTANE 28 30 225 90 1400 3100 62 PROPANE 37 222 90 1400 3100 62 NATURAL...

Page 12: ...is can corrode Use a product specifically manufactured for leak detection Greasing the taps see fig 18 19 If a tap becomes stiff to operate it must be immediately greased in compliance with the follow...

Page 13: ...YPE OF SINGLE PHASE HOTPLATE CABLE POWER SUPPLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the earth wire longer than the other conductors fig...

Page 14: ...bar Propane 37 mbar Natural 20 mbar Tot Nom Gas Rate 7 3 kW Tot Nom L P G Rate 531 g h Voltage 230 V Frequency 50 Hz 5 BURNERS Category II2H3 Butane 28 30 mbar Propane 37 mbar Natural 20 mbar Tot Nom...

Page 15: ...r adjustments Do not use re conditioned or unauthorized gas controls If repairs or adjustments are required contact our service provider on 0845 603512 specifying the type of fault and the model of th...

Page 16: ...16 V I...