background image

This Site Control Panel is all an operator

needs to see to recall memories. If only a few
presets are required, blanking an entry in the Site
Control Panel Setup removes the button from
this screen, simplifying operation. A password is
not required to operate the RPE from this screen.

If more than 16 memories are needed, they

can be saved to disk and recalled later. For
mobile sound trucks, presets for a particular
venue can be saved to disk and loaded when
returning to that venue. Printouts of device data,
graphs, and curves are available for those who
still like to file paper. These can be kept in the
project file.

Hints for Windows 95 Users

If you find yourself squeezed for room at

the bottom of the screen, you can modify the
Task Bar so it only appears when you move the
mouse pointer below the bottom of the screen.

To do this,

Right-Click on a blank spot on the task bar.
Select 

Properties

Enable 

Auto Hide

Press 

OK

.

While operating the Device Control Panel

in Windows 95, there is no button-box for the
system menu on the title bar. There is, however, a
Close-Window button-box.

As expected, the Close-Window button-box

does exit the Device Control Panel, but unfortu-
nately, it also quits RW-232.

To get back to edit mode, Right-Click the

mouse on the Device Control Panel title bar. This
will open the menu allowing you to return to
Device Edit mode or exit the program altogether.
As usual, a password is required for either
option.

Support

Accurate, simple, complete specifications

and an operator’s manual are supplied to inform
the designer and technician about the RPE 228.
These are downloadable from Rane's web site as
well. The operator’s manual features a “Quick
Start” section that gets the installer up and
running in seconds. But even easier to use than
the manual is the complete Windows Help file.
Here, many operational questions are answered.

Third-Party Support. AMX has complete

information on the Rane RPE 228 so that they
can easily incorporate the unit into any special
applications with their equipment.

In conclusion, the real key to your success

with the RPE 228 and RaneWare 232 is a little
practice (remember, the software can be used
without an actual unit attached to the PC). You
have to reach a comfort level and some enthusi-
asm for the power and simplicity of this great
approach to providing solutions. Reaching that
comfort level is easy and it will make you an
expert in front of your client.

Rane has accurately assessed the needs of

the installer and client, we are proud to provide a
superior solution that is unmatched in ease of use
and security.

Summary of Contents for rpe 228

Page 1: ...228 to ensure that reliability and critical performance criteria are met or exceeded in real world applications The unit is tamper proof meaning that when it is installed and configured it will not al...

Page 2: ...h wide unit The unit is tamper proof and does not reuqire a computer for daily operation The front panel provides critical information that is most helpful to a technician or end user While Rane subsc...

Page 3: ...ified as one of the potentially 250 devices on line in a system This way one computer can talk to and program each unit separately In addition to the above connectors the low voltage AC outboard power...

Page 4: ...eb site http www rane com A generous Help screen is included online with the RaneWare 232 software mucho pages of text but oh so easy to navigate The software is so easy to use so intuitive you ll won...

Page 5: ...ither or both channels Copy lets you transfer a curves between channels The Views menu lets you switch between viewing a single channel with graph and sliders or both sets of sliders on one screen or...

Page 6: ...reserve preset security with a computer operator the software can be locked under Device and a system password can be assigned under System Change Password The default password is please Presets can b...

Page 7: ...uits RW 232 To get back to edit mode Right Click the mouse on the Device Control Panel title bar This will open the menu allowing you to return to Device Edit mode or exit the program altogether As us...

Page 8: ...ndard protocol No extra black boxes 8 Rane Power Supply Safety agency exempt Meets safety requirements 9 Dipswitch Selectable ID Easy to set and change Access flexibility expandability 10 Steel Chassi...