background image

To change a curve without affecting the

audio in the RPE, simply select 

Local Edit

before making any changes, make them, and re-
click 

Local Edit

. You will be asked: 

Accept the

Edited Curve?

 Answering 

Yes

 sends that curve

to the RPE. While 

Local Edit

 is selected, click-

ing on any of the memory buttons displays the
preview curve without sending it to the RPE.

Device

 

brings up a selection menu of up to

15 RPE units connected to the computer. Simply
select the device you wish to control.

Devices and channels can also be given

custom names, tailored to your installation.
Simply choose 

Device

Name Device

, and the

following screen appears.

Security. The RPE can be operated on a

daily basis either through the computer, or
through the contact closures. To preserve preset
security with a computer operator, the software
can be locked (under 

Device

), and a system

password can be assigned (under 

System

,

Change Password

). The default password is

please.

Presets can be customized with names,

through 

System

Site Control Panel Setup

.

Here each memory can have a logical name.

If your installation changes by adding more

RPE units, choose  

Device

Select

, and the

POLL

 button to make the computer recognize

currently connected units in the system.

When multiple units are connected, assign

each unit a unique Device Address number. Rane
provides a special calculator to assist in setting
the dip switches on the back of each unit. Alt-
Tab to the Windows Program Manager, and in
the RaneWare program group, launch the

RaneWare 232 Address Calculator

. This

binary calculator converts decimal numbers into
corresponding dipswitch settings.

With the device locked, and a user tries to

change a curve, this friendly screen appears.

Summary of Contents for rpe 228

Page 1: ...228 to ensure that reliability and critical performance criteria are met or exceeded in real world applications The unit is tamper proof meaning that when it is installed and configured it will not al...

Page 2: ...h wide unit The unit is tamper proof and does not reuqire a computer for daily operation The front panel provides critical information that is most helpful to a technician or end user While Rane subsc...

Page 3: ...ified as one of the potentially 250 devices on line in a system This way one computer can talk to and program each unit separately In addition to the above connectors the low voltage AC outboard power...

Page 4: ...eb site http www rane com A generous Help screen is included online with the RaneWare 232 software mucho pages of text but oh so easy to navigate The software is so easy to use so intuitive you ll won...

Page 5: ...ither or both channels Copy lets you transfer a curves between channels The Views menu lets you switch between viewing a single channel with graph and sliders or both sets of sliders on one screen or...

Page 6: ...reserve preset security with a computer operator the software can be locked under Device and a system password can be assigned under System Change Password The default password is please Presets can b...

Page 7: ...uits RW 232 To get back to edit mode Right Click the mouse on the Device Control Panel title bar This will open the menu allowing you to return to Device Edit mode or exit the program altogether As us...

Page 8: ...ndard protocol No extra black boxes 8 Rane Power Supply Safety agency exempt Meets safety requirements 9 Dipswitch Selectable ID Easy to set and change Access flexibility expandability 10 Steel Chassi...

Reviews: