background image

Remote Switch External Memory Selection (Contact Closure Switch Terminals) are detach-
able Euroblock connectors. A single pole switch, several single pole switches in different
locations, or up to an eight pole switch may be used depending on the number of presets
required. A third-party touch screen with a contact closure interface would also work well.

RS 232 Control DB9 Connectors;  The INPUT connector receives direction from a PC
via a standard serial port, or is a loop-through from another RPE 228.  The OUTPUT
connector extends the communications loop to the next unit — we even supply the 18”
interconnect cable.

Device Address dipswitches allow the unit to be identified as one of the
potentially 250 devices on-line in a system. This way, one computer can talk to
and program each unit separately.

In addition to the above connectors, the low voltage AC outboard power
supply (not a wall wart!!) not only powers the RPE 228, but enables the
unit to be UL exempt... and quiet, to boot!

In summary, the front panel is tamper-proof, so that no one can alter settings.  And it

includes important information to help verify proper or improper function.  The back panel
features switches, inputs and outputs, and control points that are easy to use and require no
additional connectors.

It goes without mentioning—but we do it anyway—that the chassis is robust and cold-

rolled steel for all kinds of strength and protection, from butterfingers to RFI.

So, that’s the product.  And we are proud of it!  But remember—the real secret of the

RPE 228 is the software.

Summary of Contents for rpe 228

Page 1: ...228 to ensure that reliability and critical performance criteria are met or exceeded in real world applications The unit is tamper proof meaning that when it is installed and configured it will not al...

Page 2: ...h wide unit The unit is tamper proof and does not reuqire a computer for daily operation The front panel provides critical information that is most helpful to a technician or end user While Rane subsc...

Page 3: ...ified as one of the potentially 250 devices on line in a system This way one computer can talk to and program each unit separately In addition to the above connectors the low voltage AC outboard power...

Page 4: ...eb site http www rane com A generous Help screen is included online with the RaneWare 232 software mucho pages of text but oh so easy to navigate The software is so easy to use so intuitive you ll won...

Page 5: ...ither or both channels Copy lets you transfer a curves between channels The Views menu lets you switch between viewing a single channel with graph and sliders or both sets of sliders on one screen or...

Page 6: ...reserve preset security with a computer operator the software can be locked under Device and a system password can be assigned under System Change Password The default password is please Presets can b...

Page 7: ...uits RW 232 To get back to edit mode Right Click the mouse on the Device Control Panel title bar This will open the menu allowing you to return to Device Edit mode or exit the program altogether As us...

Page 8: ...ndard protocol No extra black boxes 8 Rane Power Supply Safety agency exempt Meets safety requirements 9 Dipswitch Selectable ID Easy to set and change Access flexibility expandability 10 Steel Chassi...

Reviews: