R&T W5100S Installation And Operation Manual Download Page 12

Emergency troubleshooting

10

 1. No water supply

Put around 2.1Gal (8L) water into a 

barrel and flush the bowl .

Note: Avoid water spilling from bowl. 

2. Replacement of battery

Unplug the DC plug of the battery box 

and remove the battery box from the 

bottom of the toilet. 
Open the battery box and replace old 

batteries. 
Insert the DC plug of battery box into the 

DC socket of toilet and then stick the 

battery box to the Velcro on the bottom 

of the toilet.

Notes: 

1. Must be 1.5V “AA” alkaline battery.
2. Different brands, different used and new batteries cannot be mixed. 
3. Battery life will be significantly reduced when using non-alkaline batteries.
4. When installing the inner box components, follow the installation direction shown in 

    the label.

Please turn on power and water supply 

when using again.

3. Product unused for a period of time

When the product is left unused for a long time, especially in cold weather, it is highly

recommended to drain the water to prevent freezing.

To discharge water

1. Activate flushing, and then turn off angle 

    valve to stop water supply.

Note: Before water discharging,

          the power must be cut off!

4. For your safety, it is recommended to 

    put antifreeze into the remaining water 

    in the bowl.

3. Disconnect the hose from angle valve, 

    drain the water and reconnect.

2. Unplug and cut off the electricity.

Summary of Contents for W5100S

Page 1: ...ate quality products to enhance your home Visit us to see our full line of products available for your home improvement needs Thank you for choosing R T Tankless Toilet Installation and Operation Guid...

Page 2: ...materials Technical drawings Toilet installation 08 After installation Maintenance Others 11 12 09 10 Daily maintenance 1 Main unit care and maintenance 2 Replacement of battery Emergency troubleshoot...

Page 3: ...ical plug with wet hands Doing so may cause electrical shock If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a...

Page 4: ...nplug the battery box immediately Do not stand on the ceramic toilet Do not hit the ceramic A heavy impact on ceramic leads to damage and water leakage Never embed ceramic toilet base in cementitious...

Page 5: ...on Bumper Seat kick button for flushing press the FLUSH button to flush full flush Flush Note 1 Button light If the battery is low when pressing the flush button the red light will flash 2 Off seat au...

Page 6: ...earance is subject to change in kind List of materials Technical drawings Please refer to the actual product Installation Manual Main Unit Hose Installation Cardboard Battery box Angle Valve Sealing F...

Page 7: ...of angle valve Line Drain outlet Angle valve Installation Method 2 15 16 14UNS NPT 1 2 Precaution before installing Minimum dynamic working water pressure 0 18 MPa 5 81 gal min or 22 L min failure to...

Page 8: ...ket with bolts and then install them to the pre installed flange plate not included on the ground and lock tight with nuts Mounting bracket Washer 5 Ceramic toilet installation Install sealing flange...

Page 9: ...ptional Apply high quality mildew glass glue around the lower edge of the toilet Glass Cement 6 Screw installation Put the screw through the fixing sleeve and then install it through the holes on both...

Page 10: ...ries Plug battery box into the DC socket of toilet and then stick the battery box to the Velcro on the bottom of the toilet When re installing the cover of battery box use your fingers to squeeze the...

Page 11: ...it care and maintenance 2 Maintenance of filter net When to maintain Poor flush performance under normal water pressure 2 Unscrew angle valve nut 1 Turn off power and the angle valve 3 Remove filter n...

Page 12: ...ed 3 Battery life will be significantly reduced when using non alkaline batteries 4 When installing the inner box components follow the installation direction shown in the label Please turn on power a...

Page 13: ...rate 3 96Gal min 15 0L min or more 0 8MPa static water pressure Installation method Glass cement Floor fixing bolts seat Caring device Open and close device Quiet soft closing device Foot touch flushi...

Page 14: ...the factory equipped cord and plug or use of a loose or faulty electrical outlet or use of a current or socket other than a 110V 60Hz electrical current from a GFI ground fused socket g Damage or los...

Page 15: ......

Page 16: ...ance and color because of products improvement please in kind prevail ASWFAF0393000A 1 2 Xiamen R T Plumbing Technology Co Ltd Add No 18 Houxiang Road Haicang District Xiamen China Tel 86 0592 6539788...

Reviews: