Remote Control Commands
R&S
®
SGT100A
490
User Manual 1176.8674.02 ─ 07
11.18 UNIT Subsystem
The
UNIT
subsystem contains the commands specifying which units are valid if no unit
is indicated in a command. These settings are valid for the entire instrument.
:UNIT:ANGLe
<Angle>
Sets the default angle unit for remote control. Does not influence the manual control
parameter units and the display.
Parameters:
<Angle>
DEGRee | RADian
*RST:
RADian
Example:
UNIT:ANGL DEG
sets DEG as a default unit for all commands which determine
angle values.
:UNIT:POWer
<Power>
Defines the default unit for power parameters. This setting affects the GUI, as well as
all remote control commands that determine power values.
Parameters:
<Power>
V | DBUV | DBM
*RST:
DBM
Example:
UNIT:POW V
sets V as a default unit for all commands which determine power
values.
11.19 List of R&S SGT Commands
:CALibration:ALL[:MEASure]?....................................................................................................................... 312
:CALibration:FREQuency:TEMPerature?...................................................................................................... 313
:CALibration:FREQuency[:MEASure]?.......................................................................................................... 312
:CALibration:IQModulator:FULL?...................................................................................................................312
:CALibration:IQModulator:LOCal?................................................................................................................. 312
:CALibration:IQModulator:TEMPerature?......................................................................................................313
:CALibration:LEVel:TEMPerature?................................................................................................................ 313
:CALibration:LEVel[:MEASure]?.................................................................................................................... 313
:CALibration<hw>:BBIN[:MEASure]?.............................................................................................................311
:CALibration<hw>:ROSCillator[:DATA]..........................................................................................................313
:CLOCk:INPut:FREQuency?..........................................................................................................................313
:CLOCk:INPut:SLOPe....................................................................................................................................314
:CLOCk:OUTPut:MODE................................................................................................................................ 314
:CONNector:REFLo:OUTPut......................................................................................................................... 314
:CONNector:USER<ch>:CLOCk:IMPedance................................................................................................ 316
:CONNector:USER<ch>:CLOCk:SLOPe.......................................................................................................316
List of R&S SGT Commands