FM Stereo Option R&S
FSV–K7S
R&S
®
FSV-K7/K7S
245
Operating Manual 1176.7561.02 ─ 06
Parameters:
<TraceMode>
<TraceMode1>, <TraceMode2>, <TraceMode3>, <Trace-
Mode4>, <TraceMode5>, <TraceMode6>
WRITe | AVERage | MAXHold | MINHold | VIEW | OFF
For details on trace modes see
*RST:
OFF,OFF,OFF,OFF,OFF,OFF
Example:
SFM:LEFT:TDOM:TYPE WRIT,OFF,AVER
Mode:
SFM
3.2.5
TRIGger Subsystem (FM Stereo, R&S
FSV–K7S)
The TRIGger subsystem is used to synchronize instrument actions with events. It is
thus possible to control and synchronize the start of a sweep.
Commands of the TRIGger Subsystem
TRIGger<n>[:SEQuence]:LEVel:SFM:LEFT
...................................................................... 245
TRIGger<n>[:SEQuence]:LEVel:SFM:RIGHt
.....................................................................245
TRIGger<n>[:SEQuence]:LEVel:SFM:MPX
.......................................................................246
TRIGger<n>[:SEQuence]:LEVel:SFM:MONO
....................................................................246
TRIGger<n>[:SEQuence]:LEVel:SFM:STEReo
..................................................................247
TRIGger<n>[:SEQuence]:LEVel:SFM:RDS
....................................................................... 247
TRIGger<n>[:SEQuence]:LEVel:SFM:PILot
...................................................................... 247
.................................................................................. 248
TRIGger<n>[:SEQuence]:LEVel:SFM:LEFT
<Level>
The command sets the level when the left stereo channel is used as trigger source.
Suffix:
<n>
.
1...4
irrelevant
Parameters:
<Level>
Range:
-10 to +10
*RST:
0 Hz
Default unit: MHz
Example:
TRIG:LEV:SFM:LEFT 2Hz
Sets the left stereo signal trigger threshold to 2 Hz.
Mode:
SFM
Manual operation:
See
TRIGger<n>[:SEQuence]:LEVel:SFM:RIGHt
<Level>
The command sets the level when the right stereo channel is used as trigger source.
Remote Commands of the FM Stereo Option (R&S