Remote Control
R&S
®
FSPN
376
User Manual 1179.4363.02 ─ 01
......................................................................................... 378
.........................................................................................379
DISPlay[:WINDow<n>]:TRACe<t>:SPURs:SUPPress
<State>
This command turns spur removal for a specific trace on and off.
Suffix:
<n>
.
1..n
<t>
1..n
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
OFF
Manual operation:
See
DISPlay[:WINDow<n>]:TRACe<t>:SPURs:THReshold
<Threshold>
This command defines a level threshold for spur removal.
Prerequisites for this command
●
Turn on spur removal (
DISPlay[:WINDow<n>]:TRACe<t>:SPURs:THReshold
).
Suffix:
<n>
.
1..n
<t>
1..n
Parameters:
<Threshold>
<numeric value>
*RST:
0
Default unit: dB
Example:
See
DISPlay[:WINDow<n>]:TRACe<t>:SMOothing[:
Manual operation:
See
[SENSe:]SPURs:SORT
<Order>
This command selects the sort order of the spurs in the spur list.
Parameters:
<Order>
POWer
Sorts spurs according to their power.
Common Measurement Settings