CDMA2000 Generator
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
935
User Manual 1173.9511.02 ─ 11
If a correction table for frequency-dependent attenuation is active for the chosen con-
nector, then the table name and a button are displayed. Press the button to display the
table entries.
Remote command:
Band / Channel / Frequency
Sets the RF carrier frequency of the generator. The relation between operating band,
frequency and channel number is defined by 3GPP2. For an overview of available
band classes see
You can specify the RF frequency in two ways:
●
Enter the frequency directly. The band and channel settings can be ignored or
used for validation of the entered frequency. For validation select the designated
band. The channel number resulting from the selected band and frequency is dis-
played. For an invalid combination no channel number is displayed.
●
Select a band and enter a channel number valid for this band. The R&S
CMW cal-
culates the resulting frequency.
Remote command:
6.3.3 Configuration of Physical Channels
The physical channels are configured via the "Level" section. It defines the levels in
physical channels of the generated forward CDMA2000 signal and configures an addi-
tive noise signal. The power, OCNS and channel settings are explained in detail below.
Fig. 6-2: Level and physical channels settings
..................................................................................... 937
GUI Reference
深圳德标仪器
135-1095-0799