GUI reference
R&S
®
ZNA
677
User Manual 1178.6462.02 ─ 20
Load File / 1x Open Preset / 1x Short Preset
Allows you to load the coupon properties from a Touchstone file (
*.s*p”
).
Remote command:
CALCulate:FMODel:ISD<Ph_pt>:COUPon:MEASure:FILename
CALCulate:FMODel:ISD<Ph_pt>:COUPon:MEASure:FILename:CLEar
CALCulate:FMODel:ISD<Ph_pt>:COUPon:MEASure:OPEN:FILename
CALCulate:FMODel:ISD<Ph_pt>:COUPon:MEASure:SHORt:FILename
CALCulate:FMODel:SFD<Ph_pt>:COUPon:MEASure:FILename
CALCulate:FMODel:SFD<Ph_pt>:COUPon:MEASure:FILename:CLEar
CALCulate:FMODel:EZD<Ph_pt>:COUPon:MEASure:FILename
CALCulate:FMODel:EZD<Ph_pt>:DUT:MEASure:FILename:CLEar
Active
the test coupon, use these checkboxes to indicate the
physical ports to which it is connected.
Table 5-8: Allowed numbers of active ports
"Sym 2x Thru"
"1x Open, 1x Short"
other
Single-ended
2
1 or 2
1
Balanced
2 or 4
2 or 4
2
Remote command:
CALCulate:FMODel:ISD<Ph_pt>:COUPon[:STATe]
CALCulate:FMODel:SFD<Ph_pt>:COUPon[:STATe]
CALCulate:FMODel:EZD<Ph_pt>:COUPon[:STATe]
5.14.5.3
Measure DUT + Test Fixture
The "Measure DUT + Test Fixture" section allows you to measure the whole structure,
i.e. the DUT with the test fixture.
For EZD this section is only available if
is enabled in the
"Advanced Settings".
Offset Embed softtool