CAUTION: DO NOT THROW ITEMS INTO THE STORAGE AREA. FAILURE TO 

HEED THESE RECOMMENDATIONS COULD RESULT IN DAMAGE TO THE 

INTERIOR OF THE CABINET.

REFRIGERATED CYCLE
Refrigerators

During the refrigeration cycle, the evaporator fans will run continuously even when 
one or more doors are open. The door switch will activate the lights when opened.
1.   Every 6 hours, the refrigeration system will turn off to allow the evaporator coil to 

defrost. The controller now displays defrost symbol. When the coil temperature 
reaches 41°F or after 20 minutes of defrost, the unit will turn on again.

2.   Anti-condensation heaters on door frames work in conjunction with the 

compressor.

3.   The factory setting for the temperature range is 34°F to 38°F.

Freezers

During the refrigeration cycle, the controller supplies power to the condensing unit 
and evaporator fan motors. The evaporator fans will run at any time when the 
evaporator coil temperature is below 54°F. They will also keep running when door 
is open but cycle off during a defrost period. The door switch will activate the lights 
when opened.
1.   Every 6 hours, the refrigeration system will turn off and electric heater will 

turn on to defrost the evaporator coil. The controller now displays the defrost 
symbol. When the coil temperature reaches 45°F or after 20 minutes of 
defrost, the unit will turn on again.

2.   Anti-condensation heaters on door frames work in conjunction with the 

compressor.

3.   The factory setting for temperature range is -7 to -3°F.

SOLID-STATE THERMOSTAT DESCRIPTIONS

Front Panel Commands
SET:

 

To display target set point; in programming mode it selects a 
parameter or confirm an operation.

 (DEF):

  To start a manual defrost.

 (UP):

 

To view the last alarm occurrence; in programming mode it browses 
the parameter codes or increases the display value.

 (DOWN):

 To view the last alarm occurrence; in programming mode it browses 

the parameter codes or decreases the display value.

 + 

 :

  To lock and unlock the keyboard.

SET + 

 :

  To enter in programming mode.

SET + 

:

  To return to the room temperature display.

:

 

To switch the instrument off.   

LED

MODE

DEFINITION

ON

Compressor enabled

FLASHING

Anti-short cycle delay enabled (AC parameter)

ON

Defrost in progress

FLASHING

Dripping in progress

ON

Fans output enabled

FLASHING

Fans delay after defrost

ON

Measurement unit

FLASHING

Programming mode

ON

Measurement unit

FLASHING

Programming mode

Main Functions

1.  HOW TO SEE THE SET POINT

a.   Push and immediately release the SET key: the display will show the set 

point value.

b.  Push and immediately release the SET key or wait for 5 seconds to display 

the sensor value again.

2.  HOW TO CHANGE THE SET POINT

a.   Hold the SET key for more than 2 seconds to change the set point value.
b.   The value of the set point will be displayed and the LED starts blinking.
c.   To change the set value, push the 

 or 

 key within 10s.

d.   To set new point value, push the SET key again or wait 10s.

3.  HOW TO START A MANUAL DEFROST

a.  Hold the key for more than 2 seconds and a manual defrost will start

4.  HOW TO LOCK THE KEYBOARD

a.   Hold the 

 and 

  keys together for more than 3s.

b.   The “POF” message will be displayed and the keyboard will be locked. At 

this point, it will be possible only to see the set point or the MAX or Min 
temperature stored.

c.   If a key is pressed more than 3s the ”POF” message will be displayed.

5.  HOW TO UNLOCK THE KEYBOARD

a.  Hold the 

 and 

   keys together for more than 3s until the “POF” 

message is displayed.

Alarm Signals

1.  HOW TO SEE THE ALARM AND RESET THE RECORDED ALARM

a.   Push the 

 or 

 key to display the alarm signals.

b.   When the signal is displayed, hold the 

SET

 key until the “rst” message is 

displayed, and push the 

SET

 key again. The “rst” message starts blinking 

and the normal temperature will be displayed.

MESSAGE

CAUSE

OUTPUTS

“P1”

Room probe failure

Compressor output according to par
“Con” and “COF”

“P2”

Evaporator probe failure

Defrost end is timed

“HA”

Maximum temperature alarm

Outputs unchanged

“LA”

Minimum temperature alarm

Outputs unchanged

“dA”

Door open

Compressor and fans restart

“EA”

External alarm

Output unchanged

“CA”

Serious external alarm (i1F=bAL)

All outputs OFF

“CA”

Pressure switch alarm (i1F=PAL)

All outputs OFF

Summary of Contents for RR27RE-S1

Page 1: ...ce This manual covers standard units only 888 994 7636 fax 888 864 7636 unifiedbrands net Information contained in this document is known to be current and accurate at the time of printing creation Un...

Page 2: ...S DANGER WARNING OR CAUTION DANGER MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY RESULT IN SEVERE PERSONAL INJURY OR DEATH WARNING MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY RESULT IN...

Page 3: ...rd SET To enter in programming mode SET To return to the room temperature display To switch the instrument off LED MODE DEFINITION ON Compressor enabled FLASHING Anti short cycle delay enabled AC para...

Page 4: ...o be alkaline based or non chloride based Any cleaner containing chlorides will damage the protective film of the stainless steel Chlorides are commonly found in hard water salts and household and ind...

Page 5: ...LIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE NOR ARE THERE ANY OTHER WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWIS...

Page 6: ...6 OM RR REACH INS Wiring Diagram RR27RE S1 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 Wiring Diagram RR27RE S1 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 CONDENSER FAN EVAPORATOR FAN GROUND...

Page 7: ...7 OM RR REACH INS Wiring Diagram RR54RE S2 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 CONDENSER FAN EVAPORATOR FAN GROUND...

Page 8: ...EACH INS Wiring Diagram RR27RE S1 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 Wiring Diagram RR27FZ S1 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 CONDENSER FAN EVAPORATOR FAN GROUND DRAIN LIN...

Page 9: ...9 OM RR REACH INS Wiring Diagram RR54FZ S2 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 CONDENSER FAN EVAPORATOR FAN GROUND DRAIN LINE HEATER...

Page 10: ...10 OM RR REACH INS Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Reviews: