background image

OM-RR REACH-INS

INSTALLATION

 

NOTE: UNIT REPAIRS WILL NOT BE SUBJECT TO STANDARD UNIT 

WARRANTIES IF DUE TO IMPROPER INSTALLATION PROCEDURES.

 

DANGER: THE UNIT MUST BE TURNED OFF AND DISCONNECTED FROM 

THE POWER SOURCE WHENEVER PERFORMING SERVICE, MAINTENANCE 

FUNCTIONS OR CLEANING THE REFRIGERATED AREA.

SELECTING A LOCATION FOR YOUR NEW UNIT

Units represented in this manual are intended for indoor use only. Be sure the 
location chosen has a floor strong enough to support the total weight of the 
cabinet and contents. A fully loaded unit can weigh as much as 1500 pounds. 
Reinforce the floor as necessary to provide for maximum loading. For the most 
efficient refrigeration, be sure to provide good air circulation inside and out.

INSIDE CABINET

Do not pack the units so full that air cannot circulate. The refrigerated air is 
discharged at the top rear of the unit. It is important to allow for proper air flow 
from the top rear to the bottom of the unit. Obstructions to this air flow can cause 
evaporator coil freeze ups and loss of temperature or overflow of water from the 
evaporator drain pan. The shelves have a rear turn up on them to prevent this. 
However, bags and other items can still be located to the far rear of the cabinet. 
Air is brought into the evaporator coil with fans mounted to the front of the coil.

OUTSIDE CABINET

Be sure that the unit has access to ample air. Avoid hot corners and locations 
near stoves and ovens. It is recommended that the unit be installed no closer 
than 2” from any wall with at least 12” of clear space above the unit.

LEVELING

A level cabinet looks better and will perform better because the doors will line 
up with the frames properly. Use a level to make sure the unit is level from front 
to back and side to side. Units supplied with legs will have adjustable bullet 
feet to make the necessary adjustments. If the unit is supplied with casters, 
no adjustments are available. Ensure the floor where the unit is to be located 
is level.

STABILIZING

All models are supplied with casters for your convenience. It is very important, 
however, that the cabinet be installed in a stable condition with the front wheels 
locked while in use. Should it become necessary to lay the unit on its side or back 
for any reason, allow at least 24 hours before start-up to allow compressor oil 
to flow back into place. Failure to meet this requirement can cause compressor 
failure and unit damage.

ELECTRICAL CONNECTION

Refer to the amperage data on page 1, the serial tag, your local code or the 
National Electrical Code to be sure the unit is connected to the proper power 
source.

IMPORTANT - READ FIRST - IMPORTANT

YOUR SAFETY AND THE SAFETY OF OTHERS ARE VERY IMPORTANT.
WE HAVE PROVIDED MANY IMPORTANT SAFETY MESSAGES IN THIS MANUAL AND ON YOUR 

APPLIANCE. ALWAYS READ AND OBEY ALL SAFETY MESSAGES.
 

  THESE ARE THE SAFETY ALERT SYMBOLS. THESE SYMBOL ALERT YOU TO 

POTENTIAL HAZARDS THAT CAN KILL OR INJURE YOU AND OTHERS. ALL SAFETY 

MESSAGES WILL FOLLOW THE SAFETY ALERT SYMBOLS AND EITHER THE 

WORDS “DANGER”, “WARNING” OR “CAUTION”.

 

  DANGER MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY RESULT 

IN SEVERE PERSONAL INJURY OR DEATH.

 

  WARNING MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY 

RESULT IN EXTENSIVE PRODUCT DAMAGE, SERIOUS PERSONAL INJURY, OR 

DEATH.

 

  CAUTION MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY RESULT 

IN MINOR OR MODERATE PERSONAL INJURY, OR PROPERTY OR EQUIPMENT 

DAMAGE.

ALL SAFETY MESSAGES WILL ALERT YOU TO WHAT THE POTENTIAL HAZARD IS, TELL YOU 

HOW TO REDUCE THE CHANCE OF INJURY, AND LET YOU KNOW WHAT CAN HAPPEN IF THE 

INSTRUCTIONS ARE NOT FOLLOWED.
IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS 

SERVICE AGENT OR SIMILARLY QUALIFIED PERSONS IN ORDER TO AVOID A HAZARD.
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH 

REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND 

KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING 

USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE 

APPLIANCE.
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS 

WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND 

KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE 

OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN 

SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER MAINTENANCE SHALL NOT BE 

MADE BY CHILDREN WITHOUT SUPERVISION.
KEEP THE APPLIANCE AND ITS CORD OUT OF REACH OF CHILDREN LESS THAN 8 YEARS.
DO NOT STORE EXPLOSIVE SUBSTANCES SUCH AS AEROSOL CANS WITH A FLAMMABLE 

PROPELLANT IN THIS APPLIANCE.
THE APPLIANCE USE FLAMMABLE INSULATION BLOWING GAS C5H10, DISPOSAL OF THE 

APPLIANCE SHALL IN ACCORDANCE WITH THE REGULATIONS OF LOCAL AUTHORITIES.
THE KEY FOR APPLIANCE ELECTRIC BOX SHOULD BE SAFE KEPT BY QUALIFIED PERSONS IN 

ORDER TO AVOID A HAZARD.

WARNING:   KEEP VENTILATION OPENINGS, IN THE APPLIANCE ENCLOSURE OR IN THE BUILT-IN 

STRUCTURE, CLEAR OF OBSTRUCTION.

WARNING:  DO NOT USE MECHANICAL DEVICES OR OTHER MEANS TO ACCELERATE 

THE DEFROSTING PROCESS, OTHER THAN THOSE RECOMMENDED BY THE 

MANUFACTURER.

WARNING:   DO NOT DAMAGE THE REFRIGERANT CIRCUIT.
WARNING:   DO NOT USE ELECTRICAL APPLIANCES INSIDE THE FOOD STORAGE COMPARTMENTS 

OF THE APPLIANCE, UNLESS THEY ARE OF THE TYPE RECOMMENDED BY THE 

MANUFACTURER.

WARNING:   HANDLING, MOVING, AND USE OF THE REFRIGERATOR OR FREEZER TO AVOID 

EITHER DAMAGING THE REFRIGERANT TUBING, OR INCREASING THE RISK OF A 

LEAK.

CAUTION:   RISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED. FOLLOW 

HANDLING INSTRUCTIONS CAREFULLY IN COMPLIANCE WITH U.S. GOVERNMENT 

REGULATIONS.

CAUTION:   COMPONENT PARTS SHALL BE REPLACED WITH LIKE COMPONENTS AND THAT 

SERVICING SHALL BE DONE BY FACTORY AUTHORIZED SERVICE PERSONNEL, SO 

AS TO MINIMIZE THE RISK OF POSSIBLE IGNITION DUE TO INCORRECT PARTS OR 

IMPROPER SERVICE.

CAUTION:   RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW 

HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED.

DANGER:    RISK OF CHILD ENTRAPMENT. BEFORE YOU THROW AWAY YOUR OLD REFRIGERATOR 

OR FREEZER: TAKE OFF THE DOORS. LEAVE THE SHELVES IN PLACE SO THAT 

CHILDREN MAY NOT EASILY CLIMB INSIDE.

Summary of Contents for RR27RE-S1

Page 1: ...ce This manual covers standard units only 888 994 7636 fax 888 864 7636 unifiedbrands net Information contained in this document is known to be current and accurate at the time of printing creation Un...

Page 2: ...S DANGER WARNING OR CAUTION DANGER MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY RESULT IN SEVERE PERSONAL INJURY OR DEATH WARNING MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY RESULT IN...

Page 3: ...rd SET To enter in programming mode SET To return to the room temperature display To switch the instrument off LED MODE DEFINITION ON Compressor enabled FLASHING Anti short cycle delay enabled AC para...

Page 4: ...o be alkaline based or non chloride based Any cleaner containing chlorides will damage the protective film of the stainless steel Chlorides are commonly found in hard water salts and household and ind...

Page 5: ...LIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE NOR ARE THERE ANY OTHER WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWIS...

Page 6: ...6 OM RR REACH INS Wiring Diagram RR27RE S1 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 Wiring Diagram RR27RE S1 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 CONDENSER FAN EVAPORATOR FAN GROUND...

Page 7: ...7 OM RR REACH INS Wiring Diagram RR54RE S2 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 CONDENSER FAN EVAPORATOR FAN GROUND...

Page 8: ...EACH INS Wiring Diagram RR27RE S1 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 Wiring Diagram RR27FZ S1 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 CONDENSER FAN EVAPORATOR FAN GROUND DRAIN LIN...

Page 9: ...9 OM RR REACH INS Wiring Diagram RR54FZ S2 CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 CONDENSER FAN EVAPORATOR FAN GROUND DRAIN LINE HEATER...

Page 10: ...10 OM RR REACH INS Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Reviews: