19

ITEM

DESCRIPTION

PART #

1

Order/Note Holder Slide, PH48SPA Units

HD SLDOSR4

1A

Order/Note Holder Slide, PH66SPA Units

HD SLD9901

2

Pan Rail Slide Back Lid, PH48SPA Units

RP LID0501

2A

Pan Rail Slide Back Lid, PH66SPA Units

RP LID0502

3

1/3 Size Pan, Scrap Catch

HD PAN037

4

Drawer Front, 27" Extendable, Top

RP FRT05T

4A

Drawer Front, 27” Extendable, Bottom

RP FRT05B

5

Sculptured Handle, 12 13/16"

HD HDL130

6

Paper Towel Dispenser Holder

RP BRK0500

7

Bracket for 1/9 size pan

RP BRK0417

8

Overshelf Assembly, PH48SPA Units

RP OSH0500

8A

Overshelf Assembly, PH66SPA Units

RP OSH0501

9

Cutting Board, 1” x 13” x 18 1/2”, PH48SPA Units only

RP CPO1318

9A

Cutting Board, 1” x 13” x 20”, PH66SPA Units only

RP CPO1320

10

Left Hinged Louver for Mech. Housing, PH48SPA Units

RP LVR0500

10A

Right Hinged Louver for Mech. Housing, PH48SPA Units

RP LVR0501

11

Left Hinged Louver for Mech. Housing, PH66SPA Units

RP LVR0502

11A

Right Hinged Louver for Mech. Housing, PH66SPA Units

RP LVR0503

12

Caster, 4 _” Overall with locking mechanism

HD CST030

12A

Caster, 4 _” Overall without locking mechanism

HD CST031

13

Vertical Adaptor Bar for Rail, 20 3/4" L with slots

PH BAR0500

13A

Vertical Adaptor Bar for Rail, 21"L x 2"W 6-Slot, PH66SPA

PH BAR221

14

Horizontal Adaptor Bar for Rail, 6 1/3" L both end hook

PH BAR0501

14A

Horizontal Adaptor Bar for Rail, 12 _” L both end hook
w/center slot, PH66SPA Units only

PH BAR0505

15

Horizontal Adaptor Bar for Rail, 4 1/4" L both end hook

PH BAR0502

16

Elbow, 1 1/2" PVC Fem x Glue

PB ELB9905

17

Pipe, 1 1/2" PVC

PB PIP150

18

Ball Valve, 1 1/2" PVC Female

PB VLV9901

19

Rod Style Cutting Board Holders with Stops, Set of 2

RP SLD0500

20

Evaporator Coil, 38"x4"x1" with brackets for PH48SPA

RF COI0304

20A

Evaporator Coil, 53”x4”x1” with brackets for PH66SPA

RF COI0002

21

Drain Screen, 2”

RP DSN002

22

Evaporator Fan Motor, Rail

EL MTR0101

23

Fan Mounting Box

RP BRK0501

Summary of Contents for PH48SPA-L-R

Page 1: ...mend that you do so at once Manufacture Service Questions 888 994 7636 P N OMANUAL_MNL0501 05 05 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 fax 888 864 7636 randell com This manual provide...

Page 2: ......

Page 3: ...d service equipment and welcome to the growing family of satisfied Randell customers Our reputation for superior products is the result of consistent quality craftsmanship From the earliest stages of...

Page 4: ......

Page 5: ...andell Manufacturing reserves the right to make changes in design and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recommended proc...

Page 6: ...window to allow for shipment installation and set up In the event equipment was shipped to a site other than the final installation site Randell will warranty for a period of three months following in...

Page 7: ...r sent back freight prepaid Decisions on whether or not to send complete condensing units will be made by Randell s in house service technician WHEN OPTIONAL LABOR EXTENSION POLICY APPLIES Randell Man...

Page 8: ...ents for previously purchased equipment SANITATION REQUIREMENTS Certain areas require specific annotation requirements other than N S F U L standards Randell must be advised of these specifications be...

Page 9: ...amages must be filed immediately within 10 days by the consignee with the freight carrier and all cartons and merchandise must be retained for inspection RETURNED GOODS Authorization for return must f...

Page 10: ...3 27 ext N A 1 3 115 10 5 15P 525 PH66SPA L R 66 40 43 68 46 36 62 x20 3 27 ext 1 27 1 2 115 12 5 15P 720 PH66SPA R L 66 40 43 68 46 36 62 x20 3 27 ext 1 27 1 2 115 12 5 15P 720 The PH48SPA L R and t...

Page 11: ...food product as well as type of operation you may need to alter this temperature Your pasta finishing table was equipped with a temperature adjustment control for the refrigerated rail located in the...

Page 12: ...other contributing factors as to the cause of the temperature variances please contact the factory at 1 800 621 8560 The base temperature can also be adjusted by the temperature control dial located...

Page 13: ...Clean all gaskets on a weekly if not daily basis with a solution of warm water and a mild detergent to extend gasket life NOTE DO NOT USE SHARP UTENSILS RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL I...

Page 14: ...disable the unit and become burdensome on your entire operation For more information on preventive maintenance consult your local service company or CFESA member Most repair companies offer this servi...

Page 15: ...difoodservice com 13 maintenance and use you will realize a profitable return on your investment and years of satisfied service...

Page 16: ...14 800 621 8560 Electrical Diagram...

Page 17: ...fan and motor 3 Compressor faulty 3 Call for service at 800 621 8561 4 Overload repeatedly tripping 4 Check outlet voltage Unit runs constantly 1 Condenser coil dirty 1 Clean coil 2 Condenser fan fau...

Page 18: ...16 800 621 8560 Replacement Parts List Pasta Finishing Tables PH48SPA L R PH48SPA R L PH66SPA L R PH66SPA R L...

Page 19: ...difoodservice com 17 Refrigerated Pan Rail PH66SPA L R shown...

Page 20: ...18 800 621 8560 Top Drawer Middle Drawer Bottom Drawer 6 1 9 Size 6 1 3 Size 6 1 3 Size 4 1 3 Size...

Page 21: ...LVR0501 11 Left Hinged Louver for Mech Housing PH66SPA Units RP LVR0502 11A Right Hinged Louver for Mech Housing PH66SPA Units RP LVR0503 12 Caster 4 _ Overall with locking mechanism HD CST030 12A Ca...

Page 22: ...Assembly RP PNL107 41 Shelf Holding Pin PH66SPA Units HD PIN0102 42 Door Gasket PH66SPA Units IN GSK9902 43 Strap Hinge Assembly for Right Hinging RP HNG9901 43A Strap Hinge Assembly for Left Hinging...

Reviews: