OM-65348-290 SELF-CONTAINED WORK-TOP FREEZER

TROUBLESHOOTING

This unit is designed to operate smoothly and efficiently if properly maintained. 
However, the following is a list of checks to make in the event of a problem. Wir-
ing diagrams are found at the end of this manual. When in doubt, turn unit off 
and contact service at 888-994-7636 or [email protected].

SYMPTOM

POSSIBLE CAUSE

PROCEDURE

Unit does not run

No power to unit

Plug in unit

Control in OFF position

Turn controller on

Faulty control

Call for service at 888-994-
7636

Unit too cold

Incorrect set point

Adjust control set point

Unit too warm

Door / drawer ajar

Ensure door / drawer is fully 
closed

Gasket torn or out of place

Inspect the gasket for wear 
and position

Incorrect set point

Adjust control set point

Warm product introduced 
to cabinet

Pre-chill product 37ºF

Ice on the coil

Initiate manual defrost

Unit noisy

Ice on the coil

Initiate manual defrost

Unit does not defrost Excessive ice on the coil

Initiate manual defrost

DANFOSS CONTROLLER CODES

DISPLAYED 

ALARM CODE

ALARM

ACTION

Hi

High Temperature Alarm

Inspect door/drawer sealing
Contact service

Lo

Low Temperature Alarm

Contact service

CON

Condenser Temperature 
High Limit 

Clean condenser coil
Inspect coil for any objects 
obstruction hindering airflow 
Contact service

uHi

Line Voltage Too High

Verify voltage of power source, 
to be performed by qualified 
technician
Contact service

uLi

Line Voltage Too Low

Verify voltage of power source, 
to be performed by qualified 
technician
Contact service

LEA

Continuous Compressor 
Runtime  

Inspect door/drawer sealing
Inspect condenser coil, clean if 
necessary
Contact service

E01

S1 Sensor Failure 

Contact service

E02

S2 Sensor Failure 

Contact service

E03

S3 Sensor Failure 

Contact service

E04

S4 Sensor Failure 

Contact service

SERVICE

CAUTION:  COMPONENT PARTS SHALL BE REPLACED WITH FACTORY OEM PARTS. 

SERVICE WORK SHALL BE DONE BY FACTORY AUTHORIZED SERVICE 

PERSONNEL, SO AS TO MINIMIZE THE RISK OF POSSIBLE IGNITION DUE TO 

INCORRECT PARTS OR IMPROPER SERVICE.

CAUTION:  BEFORE MAKING ANY REPAIRS,  ENSURE THE UNIT IS DISCONNECTED  

FROM ITS POWER SOURCE.

This piece of equipment uses a R290 Refrigeration system.  This equipment has 
been clearly marked on the serial tag the type of refrigerant that is being used.   
There is also a warning labels stating that the unit contains R290 refrigerant. R290 
is safe to use as long as you follow these warning labels.  
No smoking or open flames when servicing this equipment.  If needed, use a CO2 
or powder type fire extinguisher.
Replacement parts used on any R290 Refrigeration system cabinet must have 
specific UL certification for non-sparking components. 
Only authorized service technician, certified in R290 system should service this 
equipment.

MANIFOLD SET

A R134A manifold set can be used for servicing this equipment.  

REFRIGERANT RECOVERY

Follow all national and local regulations for R-290 refrigerant recovery.  

LEAKING CHECKING AND REPAIR

Leak check an R-290 system the same way you would an R-134a or R-404A 
system with the following exceptions. 
1.  Do not use a Halid leak detector on a R290 system.
2.  Electronic leak detector must be designated specifically for combustible gas.
Use of a bubble solution or an ultrasonic leak detector are acceptable.   
When repairing a leak, it is recommended using oxygen free dry nitrogen with a 
trace gas not exceeding 200PSI. 
When accessing an R290 system, piercing valves are not to remain on the 
equipment in a permanent manner. After charge is recovered, Schrader valves 
are to be installed on the process stubs.  Proper charge is to be weighed into the 
system and the system is to be leak checked afterwards.
The R290 equipment must have red process tubes and other devices through 
which the refrigerant is serviced, such as any service port.  This color marking 
must remain on the equipment.  If marking is removed, it must be replace and 
extend at least 2.5 centimeters (1”) from the compressor.

CHARGING

Follow the charge amount specified on the data tag.  It is recommended to use the 
shortest hoses possible to prevent undercharging.
•  Ensure the system is sealed and leak checked 
•  Evacuate system to a minimum 500 micron
•  Weigh in correct charge
•  Leak check the system again
•  Bleed the refrigerant from the high side hose to the low side hose
•  Disconnect the hoses
•  Remove line taps

Summary of Contents for 65348-290

Page 1: ...0 1 6 0 5 15P 250 INSTALLATION CAUTION THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT USE CAUTION WHEN HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER AVOID DAMAGING THE REFRIGERANT TUBING OR IN...

Page 2: ...ES TO DEFROST REFRIGERATOR DO NOT PUNCTURE REFRIGERANT TUBING RIESGO DE INCENDIO O EXPLOSI N REFRIGERANTE INFLAMABLE UTILIZADO NO UTILICE DISPOSITIVOS MEC NICOS PARA DESCONGELAR EL REFRIGERADOR NO PER...

Page 3: ...tion of warm water and a mild detergent to extend gasket life 3 Lubricate door hinges with lithium grease RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INCLUDE THE FOLLOWING JOB CLEANING AGENT COMMENT...

Page 4: ...NG ANY REPAIRS ENSURE THE UNIT IS DISCONNECTED FROM ITS POWER SOURCE This piece of equipment uses a R290 Refrigeration system This equipment has been clearly marked on the serial tag the type of refri...

Page 5: ...COIL MOUNT RC300 6 PB ELB504 ELBOW 3 8 90 CU C X C 7 RF COI9905 COIL 4 X 7 5 X 21 8 RF FAN1401 FAN AXIAL EVAPORATOR 119MM X 38MM 115V 9 RF FAN0703 FAN GUARD NICKEL CHROME FINISH WIRE 116MM RND 10 EL...

Page 6: ...1704 SUPPORT RIGHT SHELF 65348 T07 1136 4 RP SPC1701 SPACER PANEL FRONT MULLION 5 HD CST1301 CASTER LOCKING HEIGHT ADJUSTABLE 6 000 TO 6 812 5A HD CST1207 CASTER HEIGHT ADJUSTABLE 6 000 TO 6 812 PNFG3...

Page 7: ...3 46 X 9 00 X 5 90 CONDENSER 4 RF FLT9902 DRYER 1 4x 042 FILTER EKP 032 SC DBL INL CAP TUBE N 5 RP SHD1702 SHROUD FAN 65348 65360 PANDA 6 RP CPN1701 DRAIN PAN COMPRESSOR PANDA 7 RF FAN1401 FAN AXIAL...

Page 8: ...R HINGE 4 HD HDL0103 HANDLE BLACK 5 4x1 4 HD HDL251 5 RP HNG023 HINGE TOP L BRACKET W O COLLAR 6 RP HNG035 HINGE TOP DOOR CHANNEL RIGHT HAND 7 RP HNG034 HINGE TOP DOOR CHANNEL LEFT HAND 8 RP HNG9901 H...

Page 9: ...9 OM 65348 290 SELF CONTAINED WORK TOP FREEZER Electrical Schematic...

Page 10: ...M 65348 290 SELF CONTAINED WORK TOP FREEZER Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed...

Page 11: ...RANGEMENT PIED CUBE CONSOMMATION LECTRIQUE KW PAR JOUR COMPRESSEUR VOLTS AMPS NEMA POIDS L EXP DITION LB 65348 290 122 cm 48 po 84 cm 33 po 91 44 cm 36 po 2 12 89 4 02 1 2 115 60 1 6 0 5 15P 250 Poid...

Page 12: ...IER INT RIEUR DU PANNEAU DE L VAPORATEUR EXT RIEUR DE L APPAREIL RISK OF FIRE OR EXPLOSION FLAMMABLE REFRIGERANT USED DO NOT USE MECHANICAL DEVICES TO DEFROST REFRIGERATOR DO NOT PUNCTURE REFRIGERANT...

Page 13: ...s de pr f rences avec une solution d eau ti de et d un d tergent doux pour prolonger la vis des joints 3 Lubrifier les charni res de porte avec de la graisse au lithium LES PRODUITS NETTOYANTS SUIVANT...

Page 14: ...IT S SONT DISONNECTED DE SES SOURCES D NERGIE Cet appareil utilise un syst me de r frig ration R290 Le type de r frig rant utilis est clairement indiqu sur l tiquette du num ro de s rie de l appareil...

Page 15: ...ELB504 COUDE 0 95 CM 3 8 PO 90 CU C X C 7 RF COI9905 SERPENTIN 10 X 19 X 53 34 CM 4 X 7 5 X 21 PO 8 RF FAN1401 VENTILATEUR AXIAL DE L VAPORATEUR 119MM X 38MM 115V 9 RF FAN0703 GRILLE DE PROTECTION FI...

Page 16: ...36 4 RP SPC1701 PANNEAU ENTRETOISE MONTANT INTERM DIAIRE AVANT 5 HD CST1301 ROULETTE VERROUILLABLE HAUTEUR R GLABLE 15 24 CM 6 000 PO 17 3 CM 6 812 PO 5A HD CST1207 ROULETTE HAUTEUR R GLABLE 15 24 CM...

Page 17: ...902 FILTRE DE S CHOIR 1 4 X 0 042 EKP 032 SC AVEC TUYAU DOUBLE OU ES 5 RP SHD1702 COUVERCLE DU VENTILATEUR 65348 65360 PANDA 6 RP CPN1701 BAC DE VIDANGE DU COMPRESSEUR PANDA 7 RF FAN1401 VENTILATEUR A...

Page 18: ...G023 SUPPORT SUP RIEUR EN L DE LA CHARNI RE SANS COLLIER 6 RP HNG035 SUPPORT DE CHARNI RE SUP RIEUR PORTE DROITE 7 RP HNG034 SUPPORT DE CHARNI RE SUP RIEUR PORTE GAUCHE 8 RP HNG9901 CHARNI RE FERMETUR...

Page 19: ...ONDENSEUR VENTILATEUR 1 VENTILATEUR 2 VENTILATEUR DE L VAP 1 BLEU BLANC BLEU BLANC VENTILATEUR DE L VAP 2 LIMITE DE D GIFRAGE L MENT CHAUFFANT DE D GIVRAGE 115V CHAUFFERETTE AVANT 1 CHAUFFERETTE AVANT...

Page 20: ...G LATEUR AVEC SURFACE DE TRAVAIL AUTONOME Journal d entretien N de mod le Achet de N de s rie Emplacement Date d achat Date d installation N du bon de commande Pour un appel de service Date Entretien...

Reviews: