Fault
code
Fault content
Code visible
Steps for maintenance methods
E1
Temperature sensor
fault in refrigerating
chamber
Yes
Step 1: Check whether the terminal CN1 is well stuck,
pull out the terminal and re-stick it in place
Step 2: Check to see if there’re foreign matters on the
terminal. Pull out the refrigerating sensor according to
the method in described in Article 8.4 and then inspect
the sensor against the resistance value table in 10.8.
Step 3: Replace main control board
Step 4: Replace electrical wiring main harness
E2
Temperature sensor
fault
in
freezing
chamber
Yes
Step 1: Check whether the terminal CN1 is well stuck,
pull out the terminal and re-stick it in place
Step 2: Check to see if there’re foreign matters on the
terminal. Pull out the defrost sensor in freezing chamber
according to the method in described in Article 8.4 and
then inspect the sensor against the resistance value table
in 10.8.
Step 3: Replace main control board
Step 4: Replace electrical wiring main harness
E4
Defrost sensor fault
in
refrigerating
chamber
Yes
Step 1: Check whether the terminal CN3 is well stuck,
pull out the terminal and re-stick it in place
Step 2: Check to see if there’re foreign matters on the
terminal. Pull out the defrost sensor in freezing chamber
according to the method in described in Article 8.4 and
then inspect the sensor against the resistance value table
in 10.8.
Step 3: Replace main control board
Step 4: Replace electrical wiring main harness
E5
Defrost sensor fault
in freezing chamber
Yes
Step 1: Check whether the terminal CN3 is well stuck,
pull out the terminal and re-stick it in place
Step 2: Check to see if there’re foreign matters on the
terminal. Pull out the defrost sensor in freezing chamber
according to the method in described in Article 8.4 and
then inspect the sensor against the resistance value table
in 10.8.
Step 3: Replace main control board
Step 4: Replace electrical wiring main harness
E6
Communication fault
Yes
Step 1: Check whether the terminal CN8 of the main
control board is well stuck, pull out the terminal and
re-stick it in place, and check if there is any foreign
matter on the terminal.
Step 2: Replace main control board.
Step 3: Replace display control board.
Step 4: Check whether the signal cables of the main
display board are connected.
E7
Ambient temperature
sensor fault
Yes
Step 1: Check whether the terminal CN2 of main
control board is well stuck, pull out the terminal and
re-stick it in place and check if there is any foreign
Summary of Contents for COMBI Series
Page 6: ...6...
Page 8: ...8...
Page 9: ...9...
Page 10: ...10 1 2 Safety instruction for refrigerant...
Page 16: ...16 4 Terms 4 1 Definition of model None 4 2 Location of nameplate None...
Page 19: ...19 5 5 Circuit diagram...
Page 37: ...37 9 Function and operation 9 1 Operation panel SO BCD482WE ST_22031040001081 Inner display...
Page 48: ...48 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic...
Page 49: ...49 11 2 No working of compressor...
Page 51: ...51 11 5 Light is not on...