18
DRY VACUUM USER MANUAL
866-DTE-INFO
dentalez.com
PN: 7717-001C
ELECTRICAL (CONTINUED)
For electrical ratings*, refer to
SECTION I - INTRODUCTION - SPECIFICATIONS
.
6 FT CONDUIT & WIRES
(CONNECTS TO DISCONNECT)
DISCONNECT
POWER PANEL
(DEDICATED BREAKERS)
VACUUM UNIT
RAMVAC SUPPLIED
EQUIPMENT
OWNER/CONTRACTOR
SUPPLIED EQUIPMENT
*NOTES:
1.
Recommendations only. Ensure compliance with national and local codes.
2. Fuses must have time delays or be otherwise suitable for motor circuit.
3. Disconnect must be fusible and sized per UL 98, UL 489 or UL 508. Must be supplied and installed by a licensed
electrician.
4. Motors are NEMA rated. See NEMA guidelines for applicable voltage and frequency range.
WARNING
To avoid the risk of electrical shock, this equipment must only be connected to a supply mains with protective
earth.
SINGLE-PHASE CONNECTIONS
SECTION III - INSTALLATION