3
www.DentalEZ.com
866-DTE-INFO (opt 4)
3
www.DentalEZ.com
Installation by an authorized RAMVAC dealer
service technician is recommended.
NOTICE
Do not modify the Badger LF without
permission from RAMVAC. Modification will void
the warranty and could result in serious injury.
WARNING
For any questions about an order, please
contact a RAMVAC customer service
representative at
866-DTE-INFO
.
NOTICE
Section I Introduction
= Caution
= Warning
= Biohazard
= Hot Surfaces
= General Mandatory Action
= Refer to Manual (follow instructions)
= Box Must Remain Upright
= Do Not Place Box On Unlevel Surface
= Do Not Stack Box
= Box Contents Safe Temperature Range
= Box Contents Safe Humidity Range
= Protective Earth
= Hazardous Moving Parts
Explanation of Signs & Symbols
-29ºC
(-20ºF)
74ºC
(165ºF)
0%
95%
-29ºC
(-20ºF)
74ºC
(165ºF)
0%
95%
-29ºC
(-20ºF)
74ºC
(165ºF)
0%
95%
-29ºC
(-20ºF)
74ºC
(165ºF)
0%
95%
-29ºC
(-20ºF)
74ºC
(165ºF)
0%
95%
Specifications
The Badger LF Vacuum System must be
switched by a low voltage switch. It cannot be
switched with High Voltage.
NOTICE
Voltage
208-230 VAC, Single Phase
Frequency
60Hz only
Horsepower
1.5 HP
Full Load Amperes
6.2 Amps (Hi EFF motor)
Switching (low voltage)
24 VDC
Preset Vacuum Level
23.7 kPa (7" Hg)
Maximum Vacuum Level
50.8 kPa
Gauge Accuracy
ASME/ANSI B40.1 Grade B (+/-3/2/3%)
Dimensions (WxDxH)
62.74 cm x 45.72 cm x 59.06 cm (24.7" x 18" x 23.25")
Floor to Drain Center Line
19.7 cm (7.75")
Weight
79.4 kg (175 lbs)
Tank Capacity
18.9 Liters (5 gallons)
Operating Temperature
4.4°C to 40°C (40°F to 104°F)
Storage Temperature
-17.8°C to 65.6°C (0°F to 150°F)
Db Level
72db LF1 / 74db LF2
BTU Rating
900 btu/hr
Humidity in Transport/Storage/Operation
0% to 95% RH, no condensing moisture
Altitude in Operation
70-105 kPa (Sea level to 2,743m(9,000ft))
Altitude in Transport/Storage
50-105 kPa (Equates to 18,000 to - 1,000ft. elevation range