RAMSET RAM-1000 UL Instruction Manual Download Page 13

ITEM PART #

PART DESCRIPTION 

RAM-1000 UL

RAM-5500 UL

1

50-031

1/2 hp 115 vac electric motor

1

2

50-039

20 pin edge connector

1

1

3

50-058

3 1/2" uhmw idler pulley

2

2

4

50-069

limit switch 00-h3

2

2

5

50-087

# 41 x 20' gate chain

1

1

6

50-089

3/8" x 2" x 6" chain bracket

2

2

7

50-090

1/2" x 4" chain bolt

2

2

8

50-091

# 6 x 1" machine screw

2

2

9

50-092

3/8-16 x 1 1/4" hex head bolt

4

4

10

50-095

5/16-18 unc x 3/4" hex head bolt

2

2

11

50-097

5/16" flat washer

2

2

12

50-098

5/8"-11 x 3 1/2" hex head bolt

2

2

13

50-099

5/8" flat washer

2

2

14

50-101

3/8" lock washer

8

8

15

50-103

3/8" hex head nut

4

4

16

50-105

# 6 hex head nut

4

4

17

50-106

5/8" hex head nut

4

4

18

50-107

# 6 x 3/8" machine screw

3

3

19

50-113

1/2" hex head nut

4

4

20

50-114

1/4-20 socket head screw

4

4

21

50-145

1/2"  x 3" tension spring ( pedal )

1

1

22

50-151

warning sing for gate

2

2

23

50-168

horn alarm

1

1

24

50-208

limit switch nuts

2

2

25

50-212

1" tension spring

2

2

26

50-215

rocker switch

1

1

27

50-240

3/16" hot -roll metal

1

28

50-242

speed reducer size 60

1

29

50-244

polyethylene cover

1

30

50-245

limit switch chain

1

31

50-246

1" x 7" limit switch shaft

1

32

50-247

3/4" ball bearrings

2

2

33

50-248

4 pin disc release

1

1

34

50-249

1" arbor release

1

1

35

50-250

41 b 27 clutch release sprocket

1

1

36

50-251

41 b 12 x 3/4" sprocket

1

1

37

50-252

board metal cover

1

38

50-253

3/4"  shaft collar

2

2

39

50-254

spring load bracket

1

40

50-256

3/4 HP 120 VAC electric motor

1

41

50-264

1/4" x 1-1/2" key way

1

1

42

50-265

3/16" x 3/4" key way

1

1

43

50-295

#8 self-tap sheet metal screw

2

2

44

50-299

radio receiver terminal

1

1

45

50-501

3/16" hot rolled metal chassis

1

46

50-502

board metal cover

1

47

50-503

polyethylene cover

1

48

50-504

speed reducer size 50: 30:1 ratio

1

49

50-505

1" x 6" limit switch shafth

1

50

50-506

spring load bracket

1

51

50-510

outlet switch cover

1

1

52

50-511

120 vac double outlet

1

1

53

50-513

1/4" X 3/4" counter sinc bolt

2

2

54

50-514

pedal release fork 

1

1

55

50-515

limit switch chain

1

56

50-516

3/16" clutch release spring

2

2

57

50-517

1/4" x 3/8 sink screw

2

2

58

50-518

1-1/2" external snap ring 

1

1

59

50-519

3/8" x  1-1/2" carriage bolt

4

4

60

50-520

# 6 x 5/8" machine screw

4

4

61

50-540

5/16" lock nut

2

2

62

50-528

# 8 X 3/8" macine screw

4

4

63

50-777

inteligate control board

1

1

BILL OF MATERIAL FOR RAM-1000 UL AND RAM-5500 UL

R A M S E T

z

R A M S E T

z

R A M S E T

RA

MS

ET

z

RA

MS

ET

z

RA

MS

ET

- 12 -

Summary of Contents for RAM-1000 UL

Page 1: ...No 545327 US C Instruction Manual Model RAM 1000 UL RAM 5500 UL For Class I II III IV Vehicular Gate Operators Rev 060202...

Page 2: ...a rigid object or stop when an object activates the non contact sensors After adjusting the limit of travel retest the Vehicular Gate Operator Failure to adjust and retest the Vehicular Gate Operator...

Page 3: ...nt protection device or devices must be located in the line of sight of the gate Outdoor or easily acces sible controls shall have a security feature to prevent unauthorized use f All warning signs an...

Page 4: ...2 inches per second Reduction By worm gearbox continually lubricated in an oil bath By worm gearbox continually lubricated in an oil bath Finish Chassis Rust preventing Gold Zinc coated 3 16 sheet met...

Page 5: ...rs and wire mesh 5 Mix concrete pour mixture into form Tamp mixture Level and finish surface after pouring is complete 6 Allow pad to cure 48 hours and remove forms Figure 1 6 1 2 6 MIN 4 MIN WALL 4 6...

Page 6: ...IN FEET USING COPPER WIRE BY WIRE SIZE INPUT POWER MOTOR HP RECOMMENDED WIRE GAUGE VOLTAGE DROP CHART Low voltage control wires must be run in a separate conduit to the operator E D Rear Installation...

Page 7: ...switches for manual operation of the gate see Figure 7 The open stop and close buttons can be utilized to set limit switches and verify proper system opera tion when installing or servicing an operat...

Page 8: ...te is clear of people or obstructions BEFORE turning power ON to avoid injury nWARNING ALWAYS TURN OFF POWER WHEN SERVICING OPERATOR MAIN CPU CHIP OPEN FULLY OPEN FULLY CLOSED ALARM JP6 1 2 A 10 A JP5...

Page 9: ...moving until a close contact is reached DIP SWITCH A8 LOW ERD HIGH ERD Sensitivity DIP FUNCTION off Normal ERD sensitivity Adjusts the ERD for standard sensitivity on Adjusts the ERD sensitivity so t...

Page 10: ...UT DESCRIPTION Limit 1 Limit 2 Depending on dip switch B7 see dip switch features stops the motor from moving in one direc tion These wires are preset in factory and should not be moved Becomes active...

Page 11: ...MOTOR 1 AC HOT NEUTRAL MAG SOLENOID CLOSE Figure 10 3 Wire Radio Receiver Capacitor Radio Terminal Strip Mag Lock Solenoid BL BK BK RD WH Legend RD Red WH White BL Blue GR Green Ground BK Black YL Ye...

Page 12: ...INSTALLATION 6 feet min typical Inside Property Outside Property Twist wires outside of loop 3 feet min Reversing Loop Reversing Loop Exit Loop 3 feet min 3 feet min Figure 11 4 feet min 4 feet min 4...

Page 13: ...7 limit switch shaft 1 32 50 247 3 4 ball bearrings 2 2 33 50 248 4 pin disc release 1 1 34 50 249 1 arbor release 1 1 35 50 250 41 b 27 clutch release sprocket 1 1 36 50 251 41 b 12 x 3 4 sprocket 1...

Page 14: ...8 45 62 26 52 51 21 61 20 11 8 47 22 6 7 19 43 44 16 5 58 36 42 13 48 1 33 34 41 3 12 14 57 17 56 59 35 15 23 53 54 55 38 24 63 RAM 1000 UL PARTS DIAGRAM RAMSETz RAMSETz RAMSET R A M S E T z R A M S E...

Page 15: ...re 14 4 20 32 31 39 25 37 18 60 2 58 27 62 26 52 51 21 61 20 11 8 29 22 6 7 19 43 44 16 5 58 36 42 13 28 40 33 34 41 3 12 14 57 17 56 59 35 15 23 53 54 55 38 24 63 RAMSETz RAMSETz RAMSET R A M S E T z...

Page 16: ...system intended for use in a home of one to four single family dwellings or a garage or parking area associated therewith COMMERCIAL GENERAL ACCESS VEHICULAR GATE OPERATOR CLASS II A vehicular gate o...