Storage of Appliance
Always wait for the appliance to cool down before attempting to transport or store. Storage of a
stove for transport or indoors is only permissible if the cylinder is disconnected and removed
from the appliance. When the appliance is not to be used for a period of time it should be
stored in its original packaging and stored in a dry dust free environment.
ASSEMBLY INSTRUCTIONS
CAUTIONS
The burner must be installed only by a licensed gas fitter/plumber.
Do not install a damaged burner. Contact your service agent or the supplier.
Check the gas type of the burner and make sure the burner is connected to the gas type
specified on the data plate.
Before connection, ensure that there is no debris caught in the head of the gas cylinder,
hose, burner and burner ports.
Please always ensure that adequate fresh air ventilation is provided.
The burner must only be used on a level firm non-combustible surface.
The use of an adjustable wrench is required.
CLEARANCE
Minimum clearance from high pressure burner to rear or sidewall must be NO LESS THAN
1,000mm, and to the ceiling above must be NO LESS than 2,700mm.
The burner SHALL NOT be installed, or used, in a position where it could create a fire hazard.
ASSEMBLY
1. Remove all packing material and literature from the cooker
2. Connect the regulator to the LPG cylinder and tighten the connection fully in a counter-
clockwise direction.
3. You must Check For Gas Leaks before use and whenever a fitting (hose or regulator) is
disconnected or reconnected, or cylinder is refilled – To check for leaks, open the cylinder
valve with the appliance gas valves in the ‘OFF’ position and check for leakage by brushing
a solution of detergent and water on to the connection points at the bottle and the appliance.
If bubbling is evident (may take up to 30 seconds to appear) this indicates a gas leak is
present. If disassembling, cleaning, reassembling and tightening the connection does not
rectify the leak you should close the gas cylinder valve and consult the place of purchase for
assistance.
*Only use model LF103P-100KPA regulator on model RH31LT, and model
LF103P-61KPA regulator on models HP200LPWF & HP200LPB. Contact Austcrown or
dealer for replacement.