![RAMBO HP200LPB Installation & Operating Instructions Manual Download Page 8](http://html.mh-extra.com/html/rambo/hp200lpb/hp200lpb_installation-and-operating-instructions-manual_783528008.webp)
HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS
7
Gas Type and Gas Pressure
•
Do not use any other gas type except the one specified on the label/data plate.
These models of appliances are only suitable for use with propane gas only and are set to
operate under gas pressure of 100kPa.
•
The use of any equivalent Australia Approved hose/regulator assembly compliant with the
above requirements is acceptable.
WARNING! IT MAY HAZARDOUS TO ATTEMPT TO USE OTHER TYPES OF GAS WITH
THIS APPLIANCE.
Gas Cylinder (For LP Gas Model only)
Only cylinders which comply with AS2030.1 should be used. The appliance is suitable for use
with gas cylinders of 3.9 kg to 15 kg gas capacity.
The gas cylinder should not be dropped or handled roughly! If the stove is not in use, the
cylinder must be disconnected. Replace the protective cap on the cylinder after disconnecting
the cylinder from the stove.
WARNING! IT MAY HAZARDOUS TO USE DAMAGED OR DENTED GAS CYLINDER.
Gas cylinders shall be changed in a well-ventilated location, preferably outside away from
people and any sources of ignition, such as naked flames, pilot flames, electric
heaters/equipment
Cylinders must be stored outdoors in an upright position and out of the reach of children. The
cylinder must never be stored under direct sunlight or where temperatures can reach over 50
°
C.
Do not store the cylinder near flames, pilot lights or other sources of ignition. DO NOT SMOKE
around the cylinders.
WARNING! IT MAY HAZARDOUS TO STORE GAS CYLINDER IN AN ENCLOSED PLACE.
Hose
Use only gas hose complies with AS/NZS1869. The appliance required a ‘Class C’ Gas hose,
with a ¼” BSPF threaded swivel nut with 60º inverted flare connected to the gas inlet of the
appliance. The hose should be secured to the regulator and the appliance with spanner. Use
the hose with the right threads, DO NOT use adaptors.
WARNING! IT MAY HAZARDOUS TO USE WRONG TYPE OF HOSE.
The life expectancy of the hose is estimated as 5 years. It is recommended that it the hose is
changed every 5 years.
The use of the wrong hose is unsafe; always check that you have the correct items before
operating the stove.
The hose used must conform to the relevant standard for the country of use. The length of the
hose must not excess 1.8 metres (maximum). A worn or damaged hose must be replaced.
Ensure that the hose is not obstructed, kinked, or in contact with any part of the stove other than
at its connection.
WARNING! IT MAY HAZARDOUS TO USE A DAMAGED HOSE.
Regulator
Use only Gas regulator complies with AS4621. The appliance must be used with a medium
pressure regulator with output pressure of 100kPa. Use the regulator with the right threads. DO
NOT use adaptors.
The use of any equivalent certified hose/regulator assembly compliant with the above
requirements is acceptable.
WARNING! IT MAY HAZARDOUS TO USE WRONG TYPE OF REGULATOR.