TURBORAM |
Edition C - Revision 4
Instruction Manual |
16
8.1 PROGRAMMING THE CONTROL PANEL OF THE PROVER
8.2 OVEN CONNECTIONS AND PROVER MAINTENANCE
The connection is made by a female flexible pipe measuring
3/4”. The faucet should be opened to a max of 3 kg/m3. A fil-
ter should also be placed to remove the residue in the water.
Monophasic entry (230V) + ground
- brown (230V)
- blue (neutral)
- yellow/ green (ground)
RAMALHOS is not responsible for incorrect wiring or its con-
sequences.
Remove water residues from the container on a monthly
basis.
WATER CONNECTION
ELECTRIC CURRENT CONNECTION
DRAINAGE
With the control panel ON, select the desired temperature
and humidity levels. The control panel will maintain these
parameters until they have been changed by the user.
· ON: If the control panel is turned off (OFF), press the
button for 2 seconds or more to turn it on. It will
assume the previously programmed temperature and
humidity levels.
·
INCREASE OR DECREASE value: To modify the
parameters for humidity or temperature, briefly press
the corresponding button and the value will appear on
the display. In order to alter this value use the buttons
or to increase or decrease the respective value.
To validate the selected value, briefly press the button
corresponding to the value that was altered once again.
·
REGULATING THE PROVER TEMPERATURE: To turn
the temperature regulator ON or OFF, press the
button for 2 seconds. If the led light is on, the
temperature regulator is turned on.
· REGULATING THE HUMIDITY: The humidity can only be
regulated when the led light of the button is turned
on. To turn the humidity control panel ON or OFF, press
this button for 2 seconds.
· OFF: When the button is pressed for 2 seconds or
more, the control panel goes from ON to OFF. When OFF,
the led light of the button remains on. In this situation,
the displays, outputs and buttons are turned off with the
exception of the light that can be turned on to allow for
its cleaning.
+
–
HR%