background image

 

 
This is a complete set of protections that 
monitors the main amp parameters (load 
status, signal input, temperature, current, 
etc.) in order to draw from the power sup-
ply only the precise amount of current 
required to maintain safe operation during 
hazardous or extreme working conditions.  
 
This system controls the amount of power 
that the amp delivers under three basic 
circumstances: 
 
1.- The power-on sequence, where output 
is inhibited until the amp circuits are ready 
to operate. This routine is repeated at 
every restart, not just when the power 
switch is activated. 
 
2.- When internal temperatures rise to 
near thermal shutdown point due to 
unfavourable operating conditions. Here 
the system takes control, restricting cur-
rent so as to maintain operational continu-
ity at the precise power level which the 
amp is capable of withstanding at that par-
ticular moment. 
 
3.- Excessive current consumption. This 
event usually occurs under laboratory con-
ditions (long term sinusoidal signal testing 
with dummy loads) or, for example, in field 
applications in conditions of prolonged 
acoustic howl-round. Here PMS EVO

 

system takes control to avoid any damage 
to the speakers and to prevent the mains 
breaker from tripping or the fuses blowing. 
 
 
 

 

 
The RAM Audio ICL2

 is an anticlip sys-

tem  to avoid speaker failure and provide 
more acceptable sound quality even when 
clipping occurs. With the ICL2

 system 

you don't lose the music “punch” but the 
speakers are kept under control. 
 
 
 

 

 
SOA Sentry protection effectively limiting 
the power that the amp could deliver into 
an incorrect load or to a direct short-cir-
cuit. This avoids power transistor failure. 
 

PMS EVO

™ 

-

 

Power Management 

System

SSP

™ 

SOA Sentry Protection

ICL2

™ 

-

 

Intelligent Clip Limiter

 

 
Vollständiges Set von Schutzfunktionen 
das die wichtigsten Endstufenparameter 
überwacht (Auslastung, Signaleingang, 
Temperatur und Stomstärke) um vom 
Netzanschluss nur die Menge Strom zu 
beziehen, die für den betriebssicheren 
Arbeitsablauf notwendig ist 
 
Dieses System reguliert die von der 
Endstufe abgegebenen Leistung in 3 
Fällen: 
 
1.- Anschaltevorgang: Der Ausgang wird 
gehemmt bis die Endstufe voll funktions-
bereit ist. Dieser Vorgang wiederholt sich 
bei jedem Neustart, nicht nur wenn der 
Leistungsschalter aktiviert wurde. 
 
2.- Wenn die Innentemperatur aufgrund 
ungünstiger Arbeitsbedingungen nahe des 
Grenzwertes steigt, bei dem die automa-
tische Ausschaltefunktion aktiviert würde, 
um eine Überhitzung des Systems zu ver-
meiden. In diesem Fall übernimmt das 
System die Kontrolle und reduziert die 
Stromzufuhr auf ein Niveau, dass die 
Endstufe in dieser Situation aushalten 
kann. 
 
3.- Überhöhter Stromverbrauch: Diese 
Situation tritt normalerweise unter 
Laborbedingungen (in sinusförmigen 
Langzeitsignaltests mit Dummylasten) 
oder in langanhaltenden akustischen 
Feedback Bedingungen. Hier greift das 
PMS EVO

 System ein um eine 

Schädigung der Lautsprecher zu vermei-
den und um zu verhindern dass der 
Hauptunterbrecher ausgelöst wird oder die 
elektrischen Sicherungen durchbrennen. 
 
 
 

 

Das RAM Audio ICL2

 ist ein 

Anticlipsystem das das Versagen der 
Lautsprecher vermeidet und auch wenn 
Clipping auftritt noch eine bessere 
Tonqualität gewährleistet. Mit dem ICL2

 

System verlieren Sie den “Punch” nicht, 
und der Lautsprecher arbeitet kontrolliert. 
 
 
 

 

 
SOA Die Leistung, die die Endstufe an 
inkorrekte Lasten oder an einen 
Kurzschluss abgeben könnte wird wirksam 
limitiert. Dies verhindert die Zerstörung der 
Leistungstransistoren. 
 

SSP

™ 

SOA Sentry Protection

PMS EVO

™ 

-

 

Power Management 

System

ICL2

™ 

-

 

Intelligent Clip Limiter

Protection Systems

 

 
Este es un completo set de protecciones 
que monitoriza los parámetros principales 
del amplificador (estado de la carga, señal 
de entrada, temperatura, corriente, etc.) 
para así sacar de la fuente de alimenta-
ción solo la cantidad de corriente requeri-
da para mantener una operación segura 
durante condiciones extremas de trabajo. 
 
Este sistema controla la cantidad de 
potencia que el amplificador entrega bajo 
tres circunstancias básicas: 
 
1.- La secuencia de encendido, donde la 
salida es inhibida hasta que los circuitos 
del amplificador están preparados para 
operar. 
 
2.- Cuando la temperatura interna llega 
casi al punto de bloqueo térmico debido a 
condiciones de operación desfavorables. 
Aquí el sistema toma el control restringien-
do la corriente para mantener la continui-
dad operacional al nivel de potencia preci-
so en el que el amplificador es capaz de 
resistir este particular momento. 
 
3.- Consumo de corriente excesivo. Este 
caso normalmente ocurre en condiciones 
de laboratorio (test con señal sinoidal 
durante largo tiempo con cargas ficticias) 
o, por ejemplo, en aplicaciones de campo 
en condiciones de re-alimentación acústi-
ca. Aquí el sistema PMS EVO

 toma el 

control para evitar cualquier daño en los 
altavoces y prevenir que el magnetotérmi-
co salte o los fusibles se fundan .   
 
 
 

 

El ICL2

 es un sistema anticlip que evita 

daño en el altavoz y provee de una cali-
dad de sonido más aceptable incluso 
cuando el clip está ocurriendo. Con el sis-
tema ICL2

 no pierdes el “punch” de la 

música pero el altavoz es mantenido bajo 
control. 
 
 
 

 

El sistema SOA Sentry Protection limita de 
forma efectiva la potencia que el amplifica-
dor puede entregar frente a una carga 
incorrecta o a un corto-circuito. Este evita 
fallos en los transistores de potencia. 
 

SSP

™ 

- Protección SOA Sentry

PMS EVO

™ 

-

 

Sistema manejo de 

potencia

ICL2

™ 

-

 

Limitador de clip inteligente 

Sistemas de 

Protección

13

Schutzschaltungs- 

systeme

Summary of Contents for Pi Series

Page 1: ...ON MANUAL BEDIENUNGSANLEITUNG MANUAL DE EMPLEO P 8004 155 QXPDQXDoc 4 21 2021 by C E Studio 2 s l Spain EEC ramaudio com e mail support ramaudio com Professional Power Amplifiers Pi Series Pi2 3K 5K Pi4 6K 10K ...

Page 2: ...an Um Brand oder elektrische Schläge zu vermeiden darf diese Einheit keiner starken Luftfeuchtigkeit oder Regen ausgesetzt werden Um elektrische Schläge zu vermeiden öffnen Sie diese Einheit nicht Bei Reparaturbedarf wenden Sie sich an qualifiziertes Personal Es handelt sich um ein Gerät der Klasse I VORSICHT GEFAHR EINES ELEKTRISCHEN SCHLAGES NICHT ÖFFNEN PRECAUCIÓN El signo de exclamación en el ...

Page 3: ...ks of C E Studio 2 s l All other names are trademarks of their respec tive companies 0 Sicherheitshinweise 1 Allgemeine Anweisungen 1 1 Einleitung 1 2 Allgemeine Eigenschaften 2 Lokalisierung der Funktionen 2 1 Frontplatte 2 2 Rückplatte 3 Anschluss und Inbetriebnahme 3 1 Anschlüsse 3 1 1 Dual Kanalmodus 3 1 2 Bridge Kanalmodus 3 2 Aufbau 4 Technische Spezifikationen 4 1 Schutzschaltungssysteme 4 ...

Page 4: ... grande de 4 3 con panel capacitivo táctil mediante el cual es posible controlar y gestionar cada parámetro del amplificador y de su potente DSP FIR también controlado a través de nuestro software RAM_OCS Inigualable diseño en clase H 3 pasos de alta eficacia y calidad de sonido Modelos de 2 y 4 canales con poten cias de 3000 a 10000 W Última generación de fuente de ali mentación conmutada QuantaP...

Page 5: ...ptstromschalter Position I Schaltet die Endstufe ein Position O Schaltet die Endstufe aus Anzeige Siehe Seiten 10 11 und 12 Encoder Zur Steuerung der Anzeigemenüs USB Anschluss für Firmware Update und DSP Steuerung 3 2 2 1 Frontplatte 1 1 Ver Figura Interruptor principal Posición I conecta la alimentación de corriente del amplificador Posición O desconecta la potencia Pantalla ver páginas 10 11 y ...

Page 6: ... nur in Pi Dante Version Digitale Eingänge Dante Networking AES67 und DDM kompatibel Netzkabel Zum Anschließen des Verstärkers an das Stromnetz Der Farbcode lautet Blau Neutral Brown Live einphasig Gelbgrün Schutzerde 3 2 2 Rückplatte 2 1 2 4 Lokalisierung der Funktionen 5 Controls Where and What Ver Figura Entrada de señal conectores Neutrik XLR hembra para la entrada de señal al amplificador Con...

Page 7: ...al hot 3 Negatives Signal cold Asymetrisches Signal Die Belegung der XLR Pins ist wie folgt 1 Masse 2 Signal 3 Masse ACHTUNG Wenn Sie ein asymetris ches Signal anschließen und Pin 3 nicht an Masse anschließen erzeugt dies einen Verlust von 6dB 1 4 der Leistung der Endstufe am Ausgangssignal 3 1 Anschlüsse Installation and Operation Para proceder al conexionado de la uni dad situe siempre el interr...

Page 8: ...anal para controlar independiente mente los niveles de salida de cada altavoz Ver figura Seleccione el Modo BRIDGE en el display Conecte la señal de entrada al amplifi cador por el conector de entrada XLR hembra del Canal A o canal C en una etapa de 4 canales Conecte el altavoz al Speakon del canal A o canal C en una etapa de 4 canales cableando al 1 y 2 De esta forma el pin 1 es positivo Use el b...

Page 9: ...3 Dual Channel 2 Ch models 8 4 Bridge Mode 2 Ch models ...

Page 10: ...3 Dual Channel 4 Channel models 4 Channel models 4 Bridge Mode Bridge Dual Mode 3 Channels Mode 9 ...

Page 11: ...Output Channel Level ICL Indicator shines when clip limiter system is working LIM shows RMS Peak limiters compression level T shows the channel temperature percentage System Preset Mode Way User ID Out names of current process Snapshot shows the name of current Snapshot if loaded one Default Screen Icon button to access to the Default screen 3 DSP Edit Screen Source Input to select the analog digi...

Page 12: ...REQ to asign the frequency to the selected EQ GAIN to asign the gain to the selected EQ Q to asign the Q to the selected EQ 5 Amp Info Screen Config top section OPER TIME shows the amp operation time SN MODEL shows serial number and model of the amp HW FW shows the hardware and firmware versions BACKLIGHT DIMMER to change the screen brightness AUTO OFF to automatically tuen off the screen selectab...

Page 13: ... the screen and RAM_OCS PC software 5 4 ETHERNET Tab Dynamic IP SubNet Mask information of the current IP address AUTO IP to enable disable the dynamic IP function When Auto IP is enabled amp will receive an IP from an external DHCP server When no DHCP server is present in the network amp will self asignate an IP with the Zero config protocol When Auto IP is disabled you have to manually configure...

Page 14: ...Stromverbrauch Diese Situation tritt normalerweise unter Laborbedingungen in sinusförmigen Langzeitsignaltests mit Dummylasten oder in langanhaltenden akustischen Feedback Bedingungen Hier greift das PMS EVO System ein um eine Schädigung der Lautsprecher zu vermei den und um zu verhindern dass der Hauptunterbrecher ausgelöst wird oder die elektrischen Sicherungen durchbrennen Das RAM Audio ICL2 is...

Page 15: ... 2x 1500 W 2x 2500 W 2 4x 1500 W 4x 2500 W 2 Hi Z 100V 2x 800 W 2x 2500 W 4x 800 W 4x 2500 W 1 Max output voltage 144 Vpeak 176 Vpeak 144 Vpeak 176 Vpeak Max output current 38 Apeak 50 Apeak 38 Apeak 50 Apeak Total Harmonic Distortion 0 05 Voltage Gain 26dB to 44dB 1dB step SNR 106 dBA 107 5 dBA 106 dBA 107 5 dBA Required AC Mains Operating Voltage 50Hz 60Hz 170V 265V AC 90V 140V AC 1 8 Rated Powe...

Page 16: ...factured in the EEC by C E Studio 2 s l Pol Ind La Figuera C Rosa de Luxemburgo nº 34 46970 Alaquas Valencia SPAIN Phone 34 96 127 30 54 Fax 34 96 127 30 56 http www ramaudio com e mail support ramaudio com ...

Reviews: