RAM MDi Series Operation Manual Download Page 11

 

 
In the event of incorrect connection or 
misfunctioning, the amp will activate 
one or more of its LED to warn about 
the problem. 
 
 

 

Correct function

: SGNL lights to indi-

cate signal presence. (OK Green) 
 

 

ICL:

 The Intelligent Clip Limiter is ope-

rating. 
 

 

No Signal:

 No Input Signal is reaching 

the amp. 
 

 

Protections:

 (OK Red) Several causes 

can trigger this LED, most common are: 
 
- Overheating: The amplifier has rea-
ched the maximum operational tempe-
rature. Most common cause is: the nor-
mal air flow is blocked, accumulated 
dirt, dust or object leaning against the 
grill. Check and clean periodically. 
 
- Short-circuit in the speakers’ line or in 

the speakers themselves. 

 
- Low Impedance: check speakers’ con-

nections or possible speaker disfunc-
tion. 

 
- DC in the output: the protections are 

activated to avoid damage to the spe-
akers, the unit must be sent in for 
repair to a qualified technician. 

 
- Delayed Start: As you switch on the 

amp the output to the speakers is dis-
connected. After a few seconds the 
amp will connect the speakers and 
proceed with normal functioning. 

3.3 Troubleshooting

 

 
Sollte sich eine Fehlfunktion ergeben, 
wird diese durch die LED-Anzeigen auf 
der Frontplatte angezeigt. Es gibt fol-
gende Möglichkeiten: 
 
 

 

Korrektes Arbeiten:

 SGNL leuchtet 

wenn Eingangssignal vorhanden ist. 
(OK Grün) 
 

 

ICL:

 Der Intelligent Clip Limiter ist in 

Betrieb. 
 

 

Kein Eingangssignal:

 Kein 

Eingangssignal vorhanden. 
 

 

Schutzschaltungen:

 (OK Rot) Der 

Eingriff der Schutzschaltungen kann 
sich durch folgende Gründe auslösen: 
 
- Überhitzung: Die Endstufe hat die 
maximale Arbeitstemperatur erreicht. 
Die häufigste Ursache ist 
Verschmutzung oder Blockierung der 
Luftein- und Austritte. Es ist ratsam 
diese regelmäßig zu säubern. 
 
- Kurzschluss: die Anschlusskabel oder 

ggf. die Lautsprecher auf 
Kurzschlüsse prüfen. 

 
- Unangebrachte Impedanz: Die 

Impedanz der Ausgänge ist zu niedrig. 
Instalation auf Fehlanschlüsse testen 
oder ggf. Lautsprecher auf Fehler prü-
fen. 

 
- Gleichstrom: Die Schutzschaltung 

greift ein, um die Zerstörung der 
Lautsprecher zu vermeiden. Die 
Endstufe muss von einem qualifizier-
tem Techniker überprüft werden. 

 
- Soft Start: Während des 

Inbetriebnahme der Endstufe werden 
die Lautsprecher zeitlich ausgeschal-
tet, um einen möglichen Schaden zu 
vermeiden. Nach einigen Sekunden 
schaltet die Endstufe die Lautsprecher 
automatisch ein. 

 

3.3 Problemlösung

Installation and 

 Operation

 

 
Si se produce alguna anomalia en la 
Instalación o durante el funcionamiento 
del amplificador, este indicara mediante 
los LEDs de la caratula la posible causa 
de la misma. 
 

 

Funcionamiento correcto

: el LED 

SGNL luce indicando presencia de 
señal. (OK Verde) 
 

 

ICL:

 El limitador de Clip inteligente está 

operando. 
 

 

Ausencia de señal: 

no existe señal de 

entrada al amplificador. 
 
 

 

Protecciones:

 (OK Rojo) Diversas cau-

sas pueden hacer lucir este LED, las 
más comunes son: 
 
- SobreTemperatura: actuacion de las 
protecciones del amplificador por exce-
so de temperatura. Esto puede ser 
devido a la obstruccion de las tomas de 
aire situadas en la parte trasera de la 
unidad. Es conveniente limpiar de vez 
en cuando las rejilla de entrada de aire 
de ventilacion. 
 
- Corto-circuito en la línea de altavoces 

o en estos en sí. 

 
- Baja impedancia: comprueba las 

conexiones de los altavoces o un 
posible malfuncionamiento de ellos. 

 
- Corriente continua en la salida: se 

activan las protecciones para evitar 
dalo en los altavoces, la unidad debe-
rá ser enviada a un servicio técnico 
cualificado para su reparación. 

 
- Encendido suave: cuando enciendes 

el amplificador, se desconecta la sali-
da a los altavoces. Después de unos 
segundos el amplificador vuelve a 
conectar a los altavoces y procede 
con el funcionamiento normal. 

 
 

3.3 Problemas y Soluciones

Instalación 

 y operación

10

Anschluss und 

Inbetriebnahme

ICL

OK

SGNL

ICL

OK

SGNL

ICL

OK

SGNL

ICL

OK

SGNL

ICL

OK

SGNL

ICL

OK

SGN

ICL

OK

SGNL

ICL

OK

SGNL

ICL

OK

SGNL

ICL

OK

SGNL

ICL

OK

SGNL

ICL

OK

SGNL

Summary of Contents for MDi Series

Page 1: ...UNG MANUAL DE EMPLEO P 4743 845 QXPDQXDoc 8 18 2018 by C E Studio 2 s l Spain EEC http www ramaudio com e mail contact ramaudio com Professional Power Amplifiers MDi2 1K4 2K7 6K MDi4 2K4 6K 12K MDi8 2...

Page 2: ...Um Brand oder elektrische Schl ge zu vermeiden darf diese Einheit keiner starken Luftfeuchtigkeit oder Regen ausgesetzt werden Um elektrische Schl ge zu vermeiden ffnen Sie diese Einheit nicht Bei Re...

Page 3: ...E Studio 2 s l All other names are trademarks of their respecti ve companies 0 Sicherheitshinweise 1 Allgemeine Anweisungen 1 1 Einleitung 1 2 Allgemeine Eigenschaften 2 Lokalisierung der Funktionen 2...

Page 4: ...tungsentwurf ver sichert Ihnen Leistung und Zuverl ssigkeit Wahlweise gibt es Zusatzschaltungen als Schnittstelle f r Alarmsysteme drit ter Hersteller mit GPIO Anschl ssen Versiegelter Potentiometer m...

Page 5: ...utz vor berw rmung ein geschaltet ist Rot ICL Die LED zeigt an dass der Intelligent Cliplimiter arbeitet Beleuchteter Hauptstromschalter Position I Schaltet die Endstufe ein OK gr n LED leuchtet Posit...

Page 6: ...der Eingangssignale mehrerer Konfigurationsschalter Subsonicfilter 35Hz und Bridge Siehe Seite 9 Lautsprecheranschluss Neutrik Speakonstecker zum Anschluss an Lautsprecher 2 2 R ckplatte 3 2 1 2 Lokal...

Page 7: ...l anschlie en und Pin nicht an Masse anschlie en erzeugt dies einen Verlust von 6dB 1 4 der Leistung der Endstufe am Ausgangssignal Die Endstufe MDi2 4 verf gt ber eine parallele XLR Buchse f r die Zu...

Page 8: ...lizacion indicaran la situacion independiente mente de cada canal Ver figura Apague el amplificador Coloque los commutadores de modo situados en el panel trasero del ampli ficador en la posicion Bridg...

Page 9: ...3 Dual Mode 8 4 Bridge Mode...

Page 10: ...folgt Standartkonfiguration Die Endstufe arbeitet ohne Subsonic Hochpassfilter und ohne Bridgemodus Subsonicfilter eingeschaltet Die Endstufe arbeitet mit Subsonic Hochpassfilter 35Hz und ohne Bridgem...

Page 11: ...drig Instalation auf Fehlanschl sse testen oder ggf Lautsprecher auf Fehler pr fen Gleichstrom Die Schutzschaltung greift ein um die Zerst rung der Lautsprecher zu vermeiden Die Endstufe muss von eine...

Page 12: ...n 20Hz 20kHz 0 05 Intermodulation Distortion SMPTE 0 05 Damping Factor 20Hz 500Hz 8ohm 400 Crosstalk 20Hz 1kHz 75 dB Voltage Gain 32dB Sensitivity Rated Power 8W 1 4 V 2 1 V 2 8 V 1 3 V 2 V 2 8 V 1 1...

Page 13: ...ufactured in the EU by C E Studio 2 s l Pol Ind La Figuera C Rosa Luxemburgo n 34 46970 Alaquas Valencia SPAIN Phone 34 96 127 30 54 Fax 34 96 127 30 56 http www ramaudio com e mail contact ramaudio c...

Reviews: