The different elements of the screen are as follows: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
To edit the EQ of each output, select the corresponding output in the section Edit and ensure that it's 
View option is activated. As with the Xover screen, the selected EQ curve will appear in the graphic 
window. The method of adjustment is the same as for the Input EQ section. 
 
In addition, this window allows the adjustment of the output gain of each output to enable the 
balancing of the sensitivities of the various connected amplifiers and transducers. 
Adjusting gain in this section is the same as doing it from the Input & Output Gain windows. 
 
Also available in this window is the adjustment of the output delay time. This is the same parameter as 
is available in the section Out Delay. The output delay can be adjusted to solve phase problems 
between channels. Such peculiarities can be viewed using the option Add instead of Individual View. 
When activating Add, the summed response of all activated data in the individual outputs with 
activated View option are displayed as a single blue curve. 
 
If the option Speaker in View Influence is activated and loudspeaker data is present, the electro-
acoustic response of the imported speaker data is shown. 
 

Import Data 

One of the most interesting features of the LMS244, setting it apart from other products, is the 
possibility to work with real data from the transducers or loudspeaker systems to be controlled. The 
experienced user can include this response at the end of processing to see directly on-screen the final 
electro-acoustical response and use this to make necessary adjustments to the final response in 
respect of source, loudness, room-acoustics etc.. 
To enter data it is necessary to have or obtain exported data in ASCII format from one of the following 
standard data-measurement systems: 
 

- CLIO 
- MLSSA 
- WINAIR 
- SIA Smaart Pro / Smaart Live 
- IMP 
- LAUD 
- CALSOD 
- DAAS 32 
- LoudSpeaker Lab 

 
 
 

Summary of Contents for LMS 244

Page 1: ...SOFTWARE MANUAL P 85464 074 QXPDQXDoc 11 04 2004 by C E Studio 2 s l Spain EEC http www ramaudio com e mail support ramaudio com LMS 244 Digital Controller Loudspeaker Management System...

Page 2: ...ion with gain and noise gate features for each output Each output combined with six system correctional parametric EQ s and a delay stage for run time adjustments of each loudspeaker Import of measure...

Page 3: ...computer It is also possible to protect set ups in order to prevent them from being deleted or changed inadvertently The front panel of the unit can also be locked and data input via the front panel c...

Page 4: ...cted to COM2 Processor connected to COM3 Processor connected to COM4 Should you wish to work with your processor connected to the computer connect the selected serial port COM1 4 to the LMS244 by mean...

Page 5: ...lect RAM Audio LMS244 and select Add Delete It is advisable to keep a safety copy of all configuration files that have been created with extension dsc in order to be able to use them at a later date 3...

Page 6: ...time alignment of multi channel systems INPUT EQ Allows control of Global equalizer and parameter configuration for inputs A B and M which is an internally generated mono channel 6 completely configu...

Page 7: ...ub bass in principle at the fourth output This configuration is similar to the previous one but instead of providing an auxiliary send signal it provides a mono sub bass signal derived from the summin...

Page 8: ...ut Levels Next you should configure the input and output gains according to your requirements On pressing any Gain Icon the following window appears Default values are set at 0dB except the Mono Input...

Page 9: ...nnels A and B will be set to equal values and if you adjust any one of them the other one will perform in the same way If the Link A B M is activated all the input delay times will be identical On ret...

Page 10: ...re set at Bypass with a gain of 0dB and 1000 Hz centre frequency After selecting the filter to be adjusted the type of filter required can be selected Open the list Type of Filter to see the following...

Page 11: ...EQ section the signal is presented at points named A B and M These points represent the end of each input path and the beginning of the output paths With the Routing Icons it is possible to select wh...

Page 12: ...ich is completely customisable and much more versatile than the Normal Mode It allows the customising of crossover filters taking into account the self resonant response of the transducers CAUTION THE...

Page 13: ...matching to the HF driver cut at a higher frequency Also the low band region has a boost that will need to be attenuated Starting from a 4th order Butterworth filter we can arrive from the Butterworth...

Page 14: ...culiarities can be viewed using the option Add instead of Individual View When activating Add the summed response of all activated data in the individual outputs with activated View option are display...

Page 15: ...you will enter this value as reference This value can be modified by re calling the Import Speaker Frequency Response window and updating the reference value until you see a response curve which is ap...

Page 16: ...1024 Hz Amplitude Phase 21 533 210 38184 0 00 43 066 51 68376 1 40 64 600 116 45122 1 27 86 133 42 01191 0 18 107 666 121 01157 1 14 129 199 27 09770 0 13 150 732 15 25970 0 10 172 266 19 68722 1 40...

Page 17: ...dB Phase degrees 0 0 3 69 0 00 46 9 2 32 2 60 93 8 2 12 45 42 140 6 1 49 77 71 187 5 3 18 63 61 234 4 5 06 7 78 281 3 0 36 3 60 328 1 6 02 19 82 375 0 0 54 6 87 CALSOD DAAS 32 LoudSpeaker Lab To enabl...

Page 18: ...the same temporal window in all measurements outputs and with a starting time common to all of them This way the same phase information will be obtained and the final electro acoustical addition will...

Page 19: ...se in relation to time The attack time corresponds to the time the compressor limiter takes to act and allows the transients of a signal to pass without lessening them Very short attack times lead to...

Page 20: ...t stop with the entry of limiters Compressor Limiter parameters In the section CRI Knee the choice between Compressor and Limiter can be made It is important to remember that a C R I Limiter includes...

Page 21: ...44 incorporates an independent Noise Gate per output The noise gate option can be turned on off by means of the Bypass button The Bypass button appears in red in the case of a deactivated noise gate T...

Page 22: ...utput of one channel of the power amplifier at the impedance of the connected loudspeaker Amplifier Gain linear Amplifier gain factor This factor is adjustable as a linear value with the corresponding...

Page 23: ...position in which the current configuration will be stored in the LMS244 Depending on whether the software is used in online or offline mode some icons on the tool Bar will remain inactive Saving Conf...

Page 24: ...or Read Configurations from the Configuration menu After the data has been transmitted the configuration parameters will be available in the relevant windows The remote switching of the current config...

Page 25: ...with access only able to be restored with the help of a connected PC and the software program To protect the LMS244 by means of a password select the button Set Password in the tool bar or Password i...

Page 26: ...ns the following window With the help of this window the user is able to copy all or part of the configuration from one output to another With Copy Output the number of the output to be copied is sele...

Reviews: