6.2 Connecting the PoE Adapter

Step 1.

 Connect the Ethernet cable from the enclosure to the Ethernet port labeled POE on the adapter.

Step 2.

 Connect an Ethernet cable from your LAN network to the Ethernet port labeled LAN on the adapter.

Step 3.

 Connect one end of the power cord to the adapter. Connect the other end of the power cord to a power outlet.

6.3 Weather Protection

To better protect the Ethernet cable gland and the antenna connector from the weather, you need to cover them with 
PVC tape. 

Step  1. 

Clean  the  surface  area  of  the  connector  that  will  be  wrapped.  Wrap  a  layer  of  PVC  tape  with  a  50%  overlap 

according to the rotation direction of the connector. Continue wrapping the PVC tape to about 10 mm below the end of 
the connector.

Summary of Contents for RAK7289C

Page 1: ...d batteries With its new enclosure design it allows the LTE Wi Fi and GPS antennas to be inside the enclosure The gateway provides for a solid out of the box experience for quick deployment Additional...

Page 2: ...2 Packing List Device 1x Installation Bracket 1x Cable Gland 1x LoRa Antenna 1x or 2x Power Cord 1x Power Adapter 1x Waterproof Tape 1x PVC Insulating tape 1x 12V Cable 1x User Manual 1x...

Page 3: ...cy EU433 CN470 EU868 US915 AS923 AU915 IN865 KR920 Supports Quectel EG95 E EG95 NA IoT M2M optimized LTE Cat 4 Module EG95 E for EMEA Region LTE FDD B1 B3 B7 B8 B20 B28A WCDMA B1 B8 GSM EDGE B3 B8 EG9...

Page 4: ...connectors are illustrated below Notes The SD card and the SIM card do not support hot swap Please always turn off the gateway before you insert or take off SIM or SD card Do not power the Gateway wi...

Page 5: ...working LoRa2 ON OFF FLASH Flash LoRa2 packet transmitting and receiving OFF Wi Fi is disabled AP Mode ON WLAN is working Flash data transmitting and receiving STA Mode Flash slowly 1Hz connection is...

Page 6: ...ow Step 2 Position and tighten the pole clamps together around the pole with bolts washers and nuts Note The diameter of the pole that is supported by the brackets is 50 100 mm If the pole diameter is...

Page 7: ...er cord to the adapter Connect the other end of the power cord to a power outlet 6 3 Weather Protection To better protect the Ethernet cable gland and the antenna connector from the weather you need t...

Page 8: ...gth Wrap three layers around the connector with a 50 overlap Hold the tape in place with your hand for a few seconds Step 3 Wrap three additional layers with PVC tape with natural uncoiling force and...

Page 9: ...required to connect via Wi Fi xxxx represents the last two bytes of the gateway s MAC address Web UI Connect via a browser to the IP address assigned to the gateway which is 192 168 230 1 by default Y...

Page 10: ...wing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the r...