background image

Documentation Center

Figure 8: RAK19016 5-24V Power Slot Module schematics

Last Updated: 

7/18/2022, 6:55:21 AM

Summary of Contents for WisBlock RAK19016

Page 1: ...d install the Arduino IDE To add the RAKwireless WisBlock Core boards to your Arduino Boards Manager install the RAKwireless Arduino BSP Product Configuration Hardware Setup RAK19016 should be attache...

Page 2: ...is no USB connector on RAK19016 the only way to upload the code is by using RAK5804 3 9 9 3 9 9 3 9 9 3 9 9 3 9 9 Figure 2 RAK19016 and RAK5804 connection to WisBlock Base Assembling and Disassemblin...

Page 3: ...me 1 First remove the screws Figure 4 Removing screws from the WisBlock module 2 Once the screws are removed check the silkscreen of the module to find the correct location where force can be applied...

Page 4: ...RAK store WARNING Battery can cause harm if not handled properly Only 3 7 4 2 V rechargeable LiPo batteries are supported It is highly recommended not to use other types of batteries with the system u...

Page 5: ...Last Updated 7 18 2022 6 55 21 AM...

Page 6: ...ower source or as a backup secondary supply Features Supports 5 V to 24 V DC voltage supply input Uses three pin screw terminal connector Compatible with LiPo rechargeable battery On board battery cha...

Page 7: ...WisBlock 5 24V Power Slot Module Interfaces RAK19016 WisBlock 5 24V Power Slot Module provides the following interfaces Three pin Screw Terminal Connector Battery Connector LEDs one for charging statu...

Page 8: ...ing this red LED is on When the battery is full this LED is weak light or off Green LED Connected to the MCU module controlled by MCU defined by the user Blue LED Connected to the MCU module controlle...

Page 9: ...g conditions may affect the device reliability Voltage Specifications The RAK19016 WisBlock 5 24V Power Slot Module is suitable for external input voltage supply The nominal input operating voltage sh...

Page 10: ...cteristic Board Dimensions The mechanical dimensions of the RAK19016 module are shown in Figure 6 below Figure 6 RAK19016 mechanical dimensions WisConnector PCB Layout Minimum Typical Maximum Unit 3 3...

Page 11: ...ow lists the operation and storage temperature requirements of RAK19016 Schematic Diagram Figure 8 shows the schematic of the WisBlock 5 24V Power Slot Module Parameter Minimum Typical Maximum Operati...

Page 12: ...Documentation Center Figure 8 RAK19016 5 24V Power Slot Module schematics Last Updated 7 18 2022 6 55 21 AM...

Reviews: