Figure 1: Right-Rear View of L051100-A

Installation

Parameter

Value

Voltage Difference in each module (mV)

≤20

IP Rating

IP65

Recommended Usage (indoor/outdoor)

Outdoor

Net Weight (kg)

~8 kg

Dimension (L/W/H, mm)

499x280x75

±3) mm

Item

Name

Model

Remarks

1

PV
Input 1

LP-16-
C02PE-02-
001

IP67, 2pins, Pin1-Positive; Pin2-Negative, Max. current 10A

2

PV
Input 2

LP-16-
C02PE-02-
001

IP67, 2pins, Pin1-Positive; Pin2-Negative, Max. current 10A

3

Output

LP-16-
C04PE-02-
001

IP67, 4pins, Pin1-Positive (Red), Pin2-Negative (Yellow-green),
Pin3-RS485A (Brown), Pin4-RS485B (Blue)

4

Power
Switch

MPB12-
SL4P-FRG3-
B7

Turn on/off the battery

5

Valve

GLS-VTB-
M12

Safety valve

6

GND

M4

Yellow-Green

Summary of Contents for RAK9155

Page 1: ...cumentation WARNING Indicates a hazardous situation that if not avoided could result in injury CAUTION Indicates a hazardous situation that if not avoided could result in minor injury or damage to the...

Page 2: ...ts shipping packaging until it is ready to be installed Do not insert foreign objects into any part of RAK9155 Do not expose RAK9155 or its components to direct flame Do not install RAK9155 near heat...

Page 3: ...the system may be deactivated Prohibitions 1 Do not install in a closed area If the module controller is installed in a closed area with no air conditioning heat may build up inside the set and cause...

Page 4: ...follow the designated way of installation the set may drop due to the strength poverty and can cause injury Keep Dry Do not touch with wet hands If you touch the set with wet hands it may cause an el...

Page 5: ...ide the product The product is dropped or the outer shell is damaged Replace the module with a new one if discharge time at room temperature is noticeably short even from fully charged DO NOT Disassem...

Page 6: ...nge V 10 0 14 6 Standard Charge Current A 8 Max Continuous Charge Current A 10 Standard Discharge Current A 8 Max Continuous Discharge Current A 10 Rated DC Power W 102 4 The short circuit current 40A...

Page 7: ...0x75 3 mm Item Name Model Remarks 1 PV Input 1 LP 16 C02PE 02 001 IP67 2pins Pin1 Positive Pin2 Negative Max current 10A 2 PV Input 2 LP 16 C02PE 02 001 IP67 2pins Pin1 Positive Pin2 Negative Max curr...

Page 8: ...ifted with one hand a handle needs to be installed The handle is fixed to the equipment with two M6 screws Before lifting the equipment please confirm that the screws are fixed securely You can remove...

Page 9: ...therwise it is difficult to do it Before cable connection make sure the pin definition of the cables connected to PV panels is correct 4 First hang the equipment on the mounting bracket then tighten t...

Page 10: ...LED blinking without turning on the Power Switch button Turn on the Power Switch even though the green LED is blinking If RAK9155 does not connect to either the load or the solar panel the green LED...

Page 11: ...ould be stored avoiding humid conditions It should be stored in a place where it can be monitored by a professional Disclaimer It should be noted that RAKwireless shall not be liable if any necessary...

Reviews: