background image

 

 
 
 
 
 

RC315/316-FE (Rev. A) 

10/100M Auto-negotiation 

Copper-to-Fiber 

Media Converter

 

 

User Manual 

 

 

 

 

 

 

 

Raisecom Technology Co., Ltd. 

Dec, 2005 

 

 

Summary of Contents for RC315

Page 1: ...RC315 316 FE Rev A 10 100M Auto negotiation Copper to Fiber Media Converter User Manual Raisecom Technology Co Ltd Dec 2005...

Page 2: ...negotiation 8 5 3 2 RC315 RC316 FE Series RJ45 in Forced Status 8 5 4 CONNECTION WITH OTHER EQUIPMENT AT OPTICAL PORT 8 6 INSTALLATION INSPECTION 9 6 1 MATCHING FIBER OPTIC CABLE WITH MEDIA CONVERTER...

Page 3: ...g it is not allowed that the optical power of transceiver s output interface is higher than that of RC315 316 FE RC315 316 FE Rev A is an integrated device which has precise elements please avoid viol...

Page 4: ...ion RC315 FE S1 Stand alone 10 100Mbps auto sensing single strand single mode 0 25km RJ45 SC PC RC315 FE S2 Stand alone 10 100Mbps auto sensing single strand single Mode 10 50km RJ45 SC PC RC316 FE S1...

Page 5: ...Interface Wavelength nm Launch Power dBmW Receiving Sensitivity dBmW Typical Range Km Attenuation dB Km RC315 FE S1 SC PC RJ45 1310 12 3 30 0 25 0 5 RC315 FE S2 SC PC RJ45 1310 12 3 30 0 25 0 5 RC316...

Page 6: ...receive link fails Optical Transmit Link TLK ON Optical transmit link works in good condition OFF and RLK ON Optical transmit link fails Optical Interface Optical Data Active ACT Flashing Transmitting...

Page 7: ...tor ON chassis power supply works normal PS1 5V indicator OFF power supply PS1 for modules works normal otherwise abnormal PS1 12V indicator OFF power supply PS1 for fans works normal otherwise abnorm...

Page 8: ...315 RC316 FE series copper to fiber media converters have the function of MDI MDIX auto negotiation so both straight through and crossover cables can be used to connect with other equipment 2 When RJ4...

Page 9: ...o Full Duplex Mode 5 3 2 RC315 RC316 FE Series RJ45 in Forced Status When RC315 RC316 series media converter is working in forced status the RJ45 duplex mode configuration of other network equipment m...

Page 10: ...e fiber 6 3 RJ45 Interface Cat 5 of twisted pair shall be used Please note that twisted pair cables shall not be longer than 100 meters For connection configuration please see Chapter 2 Connection wit...

Page 11: ...protection and 0V power cable 48V 0V 6 6 Ambience Working temperature 20 60 Humidity 5 90 non condensing 6 7 Power Supply RC315 series Stand alone 115 230V AC or 48V DC RC316 series Single Slot Chassi...

Page 12: ...N If RJ45 manual setup Half duplex If RJ45 auto sensing Auto negotiation fails working on half duplex mode 3 RJ45 manual setup Full Duplex Half Duplex OFF If RJ45 manual setup full duplex If RJ45 auto...

Page 13: ...45 interface Link status Up Down Uncontrollable 7 RJ45 interface auto negotiation Enable manual Configurable 8 RJ45 interface control Open close Configurable 9 RJ45 interface duplex status Full half d...

Page 14: ...Raisecom Technology Co Ltd 2005 Raisecom Technology Co Ltd All trademarks are the property of their respective owners Technical information may be subject to change without prior notification V36 13...