Raisecom Technology Co., Ltd.
8. Network Management
8.1. Card/Module Information Review
With network management software, the status of RC315/316 series can be reviewed at
the host site, and controlled/configured. The status information on “Show Module Info” is
as follows:
No. Status Name/Control & Configure Items
Options
Control & Configure Features
1
Module type
M, S1, S2, S3
Uncontrollable
2 Failure
transfer
Enable/disable
Configurable
3 Frame
length
1916Byte/1536Byte
Configurable
4
Receive rate
N * 32kb/s
N is Configurable
5
Transmit rate
N * 32kb/s
N is Configurable
6
RJ45 interface Link status
Up, Down
Uncontrollable
7 RJ45
interface
auto-negotiation
Enable/manual
Configurable
8
RJ45 interface control
Open/close
Configurable
9
RJ45 interface duplex status
Full/half duplex
Configurable
10
RJ45 interface rate
10M, 100M
Configurable
11
Optical Interface: transmit Link
Up, Down
Uncontrollable
12
Optical Interface: receive Link
Up, Down
Uncontrollable
13 Optical
Interface:
signal
Normal/abnormal
Uncontrollable
8.2. Module Configuration
Options such as receiving rate, transmitting rate and RJ45 interface, etc. can be
configured through “Configure Card”.
8.3. Card Reset
The host or remote-end modules can be reset through “Host Card Reset”. The frame
length after the reset is 1,916Bytes, and the working mode of port RJ45 is auto-sensing.