Raisecom
ISCOM5504-GP (A) Hardware Description
2 Components
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
10
LED
Status
Description
LINK
1/2/3/4
Green
PON interface working LED
Green: the PON interface is connected properly and there
is a registered ONU working on the interface.
Off: the PON interface is disconnected or there is no
registered ONU working on the interface.
2.2.5 Technical specifications
Table 2-8 lists technical specifications of the GPSC card.
Table 2-8
Technical specifications of the GPSC card
Parameter
Description
Dimensions
259.3 mm (Width) × 243.4 mm (Depth) × 19.8 mm (Height)
Weight
0.64 kg
Power consumption < 34.5 W
2.3 AC power module (RPA1101-SI-220S12)
2.3.1 Introduction
The RPA1101-SI-220S12 (hereinafter referred to as RPA1101) module is the AC power
module of the ISCOM5504-GP. It supports the following features:
Wide voltage input: 100–240 VAC
Rated output voltage: 12 V; rated output current: 8.3 A
Output overvoltage and overcurrent protection
Input surge current and voltage suppression
Power status LED
Operating temperature: -10 to +70°C
Turn off the power switch or disconnect the power connection before installing or
removing the power cable.
Ensure that the label on the power cable is correct before connecting the power
cable.
Use the power cable compliant with required specifications.
2.3.2 Panel and slots
The RPA1101 power module can be only inserted into slot 4 or slot 5.
Figure 2-6 shows the panel of the RPA1101 power module.