Raisecom
Gazelle S1512i-PWR (A) User Manual
4
Cables
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
30
4.6 Alarm cable
4.6.1 Introduction
The alarm interface on the switch is a 3-pin Phoenix connector interface (with spaces of 5.08
mm). When the Gazelle S1512i-PWR is in abnormal status (temperature and voltage), it can
output alarms by controlling the connection status of PINs, notify on-site maintenance
personnel, and send alarms to the NMS.
4.6.2 Appearance
The alarm cable is composed of the connector and the alarm conducting wire, as shown in
Figure 4-10.
Figure 4-10
Alarm output interface
When an alarm is generated, PIN 1 and PIN 2 are connected, and thus the alarm LED is
on.
When no alarm is generated, PIN 3 and PIN 2 are connected, and thus the alarm LED is
off.
4.6.3 Technical specifications
Table 4-10 lists technical specifications of the alarm cable.
Table 4-10
Technical specifications of the alarm cable
Parameter
Description
Connector type
5.08 mm × 3-pin Phoenix connector
Specifications
Copper core multi-strand conducting wire 16AWG (1.25 mm
2
)
Only the Phoenix connector is delivered with the Gazelle S1512i-PWR. If required,
make the alarm cable on site according to technical specifications.