Raisecom
Gazelle S1503i (A) User Manual
2
Hardware structure
Raisecom Technology Co., Ltd.
25
2.7.6 Grounding cable
Introduction
Connecting the grounding cable properly is an important guarantee to lightning
protection, shock proof, and anti-interference. When installing and using the device,
ensure that the grounding cable is properly connected; otherwise, personnel injury or
equipment damage may be caused.
The grounding cable is used to connect the Gazelle S1503i to the ground.
Appearance
The grounding cable is composed of grounding terminals and the coaxial cable. The
grounding terminal is usually an OT non-insulated terminal. The coaxial cable is a
yellow/green copper soft flame-retardant conducting wire. Figure 2-17 and Figure 2-18 show
the grounding cable and OT terminal.
Figure 2-17
Grounding cable
1 Conducting wire
2
Stripped end (connected to the OT terminal)
3 Insulating sheath
4
OT terminal
Figure 2-18
OT terminal
1
Inner radius of
soldering lug
2
Inner radius of sheath 3
Thickness of soldering
terminal