Raisecom
Gazelle S1000i-LI (A) User Manual
4 Hardware installation
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
60
4.5 Checking installation
Table 4-2 lists items to be checked after installation.
Table 4-2
Items to be checked after installation
No.
Item
Method
1
Components of the Gazelle S1000i-LI are installed properly and do not loose or fall
off.
Check
2
All screws are tightened properly.
Check
3
Cables are connected correctly without looseness or virtual connection.
Check
4
Wiring of signal cables is compliant with the engineering design documents.
Check
5
Signal cables are not damaged, disconnected, or intermediately connected.
Check
6
Labels on the two ends of the signal cable are correct, distinct, and neat.
Check
7
Pigtail of fiber should be fit into a pipe sleeve or groove for protection and it should
not be extruded by other cables or objects when it is placed outside the cabinet.
Check
8
The curvature radius of the fiber should be greater than 20 times of the diameter of
the fiber. In general, the curvature radius of the fiber is greater than 40 mm.
Check
9
The power cable and ground cable are compliant with the engineering design
documents for convenience of dilatation.
Check
10
The power cable and signal cable should be laid out separately.
Check
11
No stains or scratches on the Gazelle S1000i-LI.
Check
12
The insurance capacity of the power can support the Gazelle S1000i-LI to work
normally as the maximum power consumption.
Use a tester.
13
When making the nose of the power cable or ground cable, you should ensure that it
is welded or crimped firmly.
Check
14
The power cable and ground cable are connected reliably and the spring washer of
the ground terminal is placed upon the flat washer.
Check
15
There is enough room for heat dissipation around the Gazelle S1000i-LI and no
heavy object is placed on it.
Check
4.6 Powering on device
Power on the Gazelle S1000i-LI as below:
Step 1
The Gazelle S1000i-LI can be powered on after being inserted with the power cable and
installed properly.
Step 2
The Gazelle S1000i-LI is powered on when the power LED (PWR) is on.