Raisecom
Gazelle S1000i-LI (A) User Manual
2 Hardware structure
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
28
Parameter
Description
Welding technology
The conducting wire and OT terminals adopt solderless
pressed connection.
Error in length of
conducting wire
±5 mm
Resistance
13.7 mΩ/m
Table 2-19 lists technical specifications of the OT terminal.
Table 2-19
Technical specifications of the OT terminal
Parameter
Description
Model
Ground round-pressed terminal (M4)
Compliant standard
JB2436-78
Technical specifications
4.3 soldering lug
Inner diameter of soldering lug: 4 mm
Outer diameter of soldering lug: ≤ 8 mm
Inner diameter of sheath: 2.1 mm
Thickness of soldering lug: ≥ 0.6 mm
Cross-sectional area of
the conducting wire
16–15 AWG (1.2–1.5 mm
2
)
The Gazelle S1000i-LI is delivered with an OT terminal and without the ground
cable. If required, make the ground cable on site according to technical
specifications.
The ground cable cannot be longer than 30 m and should be as short as possible;
otherwise, a ground bar should be used instead.
2.7.2 AC power cable
Introduction
The AC power cable supplies 110/220 VAC power from the power souring equipment to the
power interface on the Gazelle S1000i-LI, and then transmits power to the entire device.
The AC power cables of the Gazelle S1000i-LI are different according to local standards, as
listed in Table 2-20.
Table 2-20
AC power cables
Regional standard
Description
Europe
POL-AC-French-3-pin/stripped-0.75mm
2
-1.5m/RoHS