4 Hardware installation
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
59
Figure 4-22
Fastening screws of the AC power cable
Step 4
Connect the other end of the AC power cable to the cabinet or the powering equipment in the
equipment room.
Connecting DC power cable
The DC power cable of the Gazelle S1000i-LI DC power model is a 5-pin Phoenix connector.
Connect the DC power cable as below:
Step 1
Make the DC power cable according to specifications.
Step 2
Insert the connector of the DC power cable into the power interface of the Gazelle S1000i-LI
properly, and fasten spring screws at both sides of the connector, as shown in Figure 4-21.
Figure 4-23
Connecting the connector of the DC power cable
Step 3
Connect the other end of the DC power cable to the cabinet or the powering equipment in the
equipment room.