81
English
RAIS/
attika
- User manual for New PILAR / PILAR 13
Remove dirt and dust, and mount the parts
in reverse order.
Note!!
be careful when replacing the smoke converter plate and smoke chikane
make sure that the tabs from on the smoke chikane ‘catches’ the holes in the stove.
Interruption of operation
Smoke spillage around door
could be due to too low draught in the chimney <12Pa
•
check whether the flue or chimney is blocked
•
check whether the extraction hood (kitchen) is switched on; if it is, switch it off and
open a window/door in the proximity of the stove for a short while.
Soot on glass
could be caused by
•
the firewood is closed.
make sure that the stove is heated properly when firing up, prior to closing the door.
Stove is burning too strong
could be caused by:
•
leak around the door seal
•
chimney draught too large >22 Pa, draught control regulator should be installed.
taps
Holes
front of stove-bottom view