RAIS 800 User Manual Download Page 5

ENGLISH                            RAIS - manual for RAIS 800                                                                      

5

RAIS 800

Nominal output (kW):

5

Min./Max.  output(kW):

4,7 - 5,5

Heating area (m

2

)

ca. 100

Stove’s width/depth/height (mm)

541-490-1227

Combustion chamber’s width/depth/height (mm)

370-380-411

Recommended amount of wood when fuelling (kg):
(Distributed on 2-3 logs of wood of approx. 25 cm)

1,5

Min. uptake (Pascal):

-12

Weight (kg):

ca. 130

Smoke gas mass flow (g/s):

6,4

Smoke gas temperature (°C):
with Nominal output

297

Intermittent operation:

Fuelling should be undertaken 

within 3 hours.

Specifications

Summary of Contents for 800

Page 1: ...ENGLISH RAIS manual for RAIS 800 1 U S E R M A N U A L RAIS 800...

Page 2: ...We cannot be held responsible for any misprints...

Page 3: ...3 INSTALLATION DISTANCE IN CASE OF COMBUSTIBLE WALL 14 15 GENERAL INSTALLATION 16 FOR THE INSTALLER 17 OPERATING INSTRUCTIONS 18 FUEL 18 DRYING AND STORAGE 19 REGULATION OF COMBUSTION AIR 19 ROOM VENT...

Page 4: ...ling and using it In the case of warranty coverage and for general queries regarding your wood burning stove it is important that you know the stove s production number We therefore recommend that you...

Page 5: ...227 Combustion chamber s width depth height mm 370 380 411 Recommended amount of wood when fuelling kg Distributed on 2 3 logs of wood of approx 25 cm 1 5 Min uptake Pascal 12 Weight kg ca 130 Smoke g...

Page 6: ...t the entire room The cold air is sucked in at the base of the stove up through the convection channel which runs along the stove s combustion chamber The heated air pours out at the top of the stove...

Page 7: ...Safety at Work Act 1974 It is the responsibility of the installer to ensure that all requirements of this Act are met during the installation works Attention is drawn in particular to the following H...

Page 8: ...tions Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immedi ately before installation of the stove If the stove is fitted in place of an open fire then...

Page 9: ...soot door or doors must be provided for sweep ing the chimney and connecting fluepipe You should also familiarise yourself with the draught conditions for chimneys with 2 flues The flue outlet spigot...

Page 10: ...structure must be able to carry the weight of the wood burning stove as well as the weight of a chimney if necessary When you choose where to set up your RAIS wood burning stove you should consider t...

Page 11: ...l when the door is closed Remove the door from the stove Be careful not to damage the glass on the door Keep the protective tape and plastic on the handles Protect the painted stove body against spray...

Page 12: ...m Mounting distance for panelled wall combustible material Insulation ability such as Aqua panel coefficient of thermal conductivity 0 36 W mk or better Distance to combustible material Min convection...

Page 13: ...ENGLISH RAIS manual for RAIS 800 13 Combustible material Min 150 Min 150 Combustible material Min 300...

Page 14: ...r ndbart min 300mm Afstand til br ndmur 0mm 50mm anbefales Mounting distance for brick wall firewall Distance to firewall 0 mm 50 mm recommended Distance to firewall 0 mm 50 mm recommended Distance to...

Page 15: ...RAIS manual for RAIS 800 15 Damage on brick walls may occur if the necessary convection are not obtained Br ndbart materia Brennbart materia Combustible material Combustible material Min 150 Min 150...

Page 16: ...wall brackets or a ceiling support plate The weight of the stove is indicated in the brochure The stove should always be installed on a non combustible hearth of a size and construc tion that is in a...

Page 17: ...onnections to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally hand ing over to the user If necessary read the later parts of this manual for guidance on...

Page 18: ...this will produce malodorous smoke which could be poisonous When firing with the above mentioned items and amounts larger than those recommend ed the stove is subjected to a larger amount of heat whi...

Page 19: ...is pre heated through the side channels and then emitted as hot scav enging air onto the glass The hot air rinses the glass and keeps it soot free The tertiary channel which can be seen at the the to...

Page 20: ...mal air intake Position 2 Push the handle towards the right until it stops This posi tion provides full secondary air intake In the event of ordinary combustion the handle is to be adjusted to the int...

Page 21: ...stove gets very hot when in use always wear protective gloves when tending the stove If the stove has not been used for a while follow the steps as if you were using it for the first time IMPORTANT W...

Page 22: ...etween the upper baffle plate and the chimney set the paper on fire and wait until you hear a rumbling noise in the chimney This means that there definitely is a draught in the chimney and you avoid s...

Page 23: ...of glowing embers add 2 3 pieces of wood Leave the door ajar until the fire has caught on properly close the door Damper see adjustment of air damper After approx 5 min or when the flames are clear an...

Page 24: ...n chamber Scrape shovel the ash out and store it in a non flammable container until it has cooled down You can dispose of ash with your normal household waste REMEMBER Never remove all the ashes from...

Page 25: ...g it to one side and turning it a little slantwise Pull out the plate carefully Then remove the smoke impediment by lifting it up and moving it forward Carefully lift out the smoke impediment There is...

Page 26: ...chimney draught too large 22 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for room ventilation unclean smok...

Page 27: ...re parts other than those recommended by RAIS are used the warranty is voided All replaceable parts can be bought as spare parts from your RAIS distributor See the following spare parts diagrams for t...

Page 28: ...ENGLISH RAIS manual for RAIS 800 28 Reservedelstegning RAIS 800 Pos Ref Quantity Item no description 1 1 5401090 95 Door 2 1 54000990 95 Air system 3 1 5302200 Fire brick set 4 5305500 Seal set...

Page 29: ...ENGLISH RAIS manual for RAIS 800 29 1 2 3 4...

Page 30: ...ENGLISH RAIS manual for RAIS 800 30...

Page 31: ...ENGLISH RAIS manual for RAIS 800 31...

Page 32: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn www rais dk...

Reviews: