E.

 

START UP & PROGRAMMING 

The control valve is controlled with simple, user-friendly electronics displayed on an LCD screen.   

When power is first supplied, the valve electronics may take up to a minute to initialize.  During this time the screen 
may show “INTIALIZING WAIT PLEASE”.  Do not touch any buttons at this time.  When the valve reaches the service 
position, it will display the following information in sequence. 

THIS IS NORMAL

 

 

1.

 

Date & Time 

2.

 

Total & Remaining Gallons 

3.

 

No. of people in the house & Reserve Capacity 

4.

 

Estimated days left for next regeneration 

5.

 

Last Regeneration date 

6.

 

Total # of regenerations 

7.

 

Total Treated Gallons of water 

8.

 

Overrun Total 

9.

 

Current and Peak water flow rate 

10.

 

Day override 

11.

 

Rinse override 

12.

 

Delayed Regeneration 

13.

 

Regeneration Time 

14.

 

Refill Time 

15.

 

Valve Model 

16.

 

Valve ID 

The control valve has a display screen and 4 buttons 

 

 

 

 

 

 

 

 

 

 

 

 

PROGRAMMING 

 

(I)

 

LANGUAGE SELECTION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SETTINGS 

 

The function of this key is to 
enter the level one 
programming mode where 
the valve settings can be 
adjusted. 

MANUAL REGEN 

 

This button has two functions.  The first is to initiate 
a manual regeneration by holding the button for 3 
or more seconds.  The second function is while in 
programming mode, pressing this key allows the 
user to change the value of each setting. 

UP / DOWN

 

These buttons are used to 
increase or decrease the value 
of the settings while in the 
programming mode. 

Press 

SETTINGS

 and 

REGEN

 

button together for 3 seconds. 
The display will beep & change 
to LANGUAGE 

LANGUAGE 

ENGLISH

 

Press 

UP

 or 

DOWN

 key to 

select your preferred language 

LANGUAGE 

ENGLISH

 

Press 

SETTINGS

 again to exit 

Language selection.  

Press 

SETTINGS

 for 3 sec. 

After 3 seconds the display will 
beep confirming unlock  

Summary of Contents for T Series

Page 1: ...o Friday 8 30 AM to 5 00 PM EST www rainfresh ca TABLE OF CONTENTS A System Specifications 2 B How Your Water Conditioner Works 2 C Safety Precautions 2 D Installation 3 a Electrical Requirements 3 b...

Page 2: ...on additional treatment that may be necessary B HOW YOUR WATER CONDITIONER WORKS Your Rainfresh Softener removes hardness using a process called Ion Exchange In this process when hard water flows thr...

Page 3: ...ce shims under the unit to level it The weight of the unit full of water and salt can cause the softener tank to crack at the shim 11 The unit should only be moved by 2 or more people due to heavy wei...

Page 4: ...ROWN INTO YOUR HOME S PLUMBING SYSTEM CAUSING DAMAGE TO IT AS WELL AS THE SOFTENER The following pipe can be used for installing your new system Copper CPVC and PEX are the most popular Installation L...

Page 5: ...ew fitting and reinstall locking clip Fig 2 Plumb in the softener using appropriate fittings Attach the drain hose 15 ft included to the drain fitting and secure it with a hose clamp Fig 4 included Ru...

Page 6: ...itical level but just helps with the process for the first regeneration Then add 2 bags 20 Kg bags of salt to start with Turn the main house shut off valve on slightly and watch for leaks Make sure a...

Page 7: ...rride 12 Delayed Regeneration 13 Regeneration Time 14 Refill Time 15 Valve Model 16 Valve ID The control valve has a display screen and 4 buttons PROGRAMMING I LANGUAGE SELECTION SETTINGS The function...

Page 8: ...ent minutes TIME OF DAY 08 51 PM 7 Press SETTINGS key again and AM PM will be highlighted 8 Now press UP or DOWN key to change AM PM value to current time 9 Press SETTINGS button again and YEAR will b...

Page 9: ...T PEOPLE 4 16 Now press UP or DOWN key to enter number of people in your household SALT SETTING STANDARD 17 Press SETTINGS again to advance to SALT SETTINGS SET PEOPLE 6 18 Leave at STANDARD factory s...

Page 10: ...IN VOL Press REGEN button to advance to RESIN VOL Default BACKWASH is set for 5 min Press UP to increase this setting if your water has high turbidity or iron Set RESIN VOL as follows Model 30T 1 00 C...

Page 11: ...can use UP arrow key to increase this setting if you prefer a more thorough rinse REFILL AUTO 2 5 MIN Press REGEN button to advance to REFILL This is set to AUTO Press REGEN to advance to LOCK VALVE...

Page 12: ...re salts Use only high grade water softener salt Sodium Chloride You can use Potassium Chloride but you will need to increase salt settings Check the salt level monthly It is important to ALWAYS maint...

Page 13: ...embly is easy to clean Shut off the water supply to your softener and reduce the pressure by opening a cold soft water faucet Using a screwdriver remove the two screws holding the injector cover to th...

Page 14: ...eaner to clean bed Increase regeneration frequency 3 Clean control valve inlet E Resin in drain line 1 Air in water system 2 Incorrect or missing drain line flow control DLFC 3 Unit sucking air during...

Page 15: ...15 I PARTS LIST...

Page 16: ...t to the original installation as determined by the company This warranty will not apply if water passing through the System has a Turbidity Suspended Solids 5 ppm mg l b Hydrogen Sulphide concentrati...

Reviews: