Disinfecting the Softener
It is possible that during shipping, storage & installing, bacteria can go into the unit.
Therefore, as a good installation practice, it is recommended that the softener be
disinfected prior to use. To disinfect, open the lid of the brine well in the salt tank and add
approx. 3 tablespoons of fresh common household bleach. Replace lid & proceed to
manual regeneration.
Manual Regeneration
To perform a manual regeneration, follow the following steps.
YOUR UNIT IS NOW READY FOR SERVICE
RINSE
4
MINUTES
Press
REGEN
button to
advance to “RINSE”
RINSE
4
MINUTES
Default RINSE is set for 4 min.
You can use
UP
arrow key to
increase this setting if you
prefer a more thorough rinse
REFILL
AUTO 2.5 MIN
Press
REGEN
button to
advance to “REFILL”. This is set
to AUTO. Press
REGEN
to
advance to LOCK VALVE
LOCK VALUE
UNLOCK
Press
UP
or
DOWN
key to
either LOCK your settings or
leave them unlocked
LOCK VALUE
LOCK
PROGRAMMING
COMPLETE
Press
REGEN
button to
advance to complete
programming
Display will briefly show
PROGRAMMING COMPLETE & go to
home screen. It will now display
various settings in sequence.
Press
SETTINGS
for 3 sec.
After 3 seconds the display will
beep confirming unlock
Press
REGEN
button again and
the
unit
will
start
the
regeneration process. This will
last for over an hour.
Press and hold
REGEN
button
and display changes to
REGENERATION.
REGENERATION
IMMEDIATELY
ADVANCING TO
BACKWASH
Open this lid &
pour bleach inside