(J) LIMITED WARRANTY 

 

This  CAFO948  System  is  warranted  to  the  original 
Consumer purchaser for a period of one (1) year, from the 
date  of  purchase,  against  defects  in  materials  or 
workmanship. The electronic controls and mineral tank are 
warranted for 5 and 10 years respectively against defects in 
materials or workmanship. The company's obligation under 
this  warranty  shall  consist  of  repair  or  replacement,  at  its 
option,  of  any  part  found  by  company  inspection  to  be 
defective, provided that the product has not been misused, 
abuse,  altered  or  damaged  by  Consumer  with  respect  to 
the  original  installation,  as  determined  by  the  company. 
This  warranty  will  not  apply  if  feed  water  does  not  meet 
specifications of this system. This limited Warranty applies 
only  to  a  unit  when  returned  to  the  Warrantor  at  the 
owner’s  expense  and  in  accordance  with  shipping 

instructions  received  from  the  Warrantor.  This  warranty 
does NOT cover, and is intended to exclude, any liability on 
the  part  of  Envirogard  for  any  incidental  damages, 
consequential damages, labour charges or any other costs 
incurred in connection with the purchase, installation, use, 
maintenance  or  repair  of  the  system  whether  under  this 
warranty  or  any  other  warranty  implied  by  law.  Some 
provinces/states do not allow the exclusion of incidental or 
consequential  damages,  so  the  above  limitation  or 
exclusion  may  not  apply  to  you.  This  warranty  gives  you 
specific  legal  rights  and  you  may  also  have  other  rights, 
which  vary  from  province/state  to  province/state.  This 
warranty  applies  only  to  CAFO948  systems  purchased  in 
Canada.

 
 
 
 
 

 

Envirogard Products Limited

 

446 Major Mackenzie Drive East, 

Richmond Hill, ON L4C 1J2, Canada 

Tel :

 (905) 884 9388 

Helpline:

 1800 667 8072  

Web:

 www.rainfresh.ca 

 

© 

COPYRIGHT   .   ENVIROGARD PRODUCTS LIMITED 2020   .   ALL RIGHTS RESERVED

 

Jun 

2020

 

 

DESCRIPTION 

Riser 

Media Tank – 9”x 48” 

Filter media (1 cu ft) 

Bottom Distributor 

Power adapter (110V) 

Inlet check valve 

Brine check valve 

 

Summary of Contents for CAFO 948

Page 1: ...ne Help Line 1 800 667 8072 Monday to Friday 8 30 AM to 5 00 PM EST www rainfresh ca TABLE OF CONTENTS A System Specifications 2 B How the CAFO System Works 2 C Safety Precautions 2 D Installation 3 a...

Page 2: ...er are used to clean the system it is recommended that you consult a professional to ascertain the safety of the water going into your septic system C SAFETY PRECAUTIONS Follow all applicable province...

Page 3: ...plete a cycle from start to shut off Well pump flow rate Volume of water collected drawdown Time for pump cycle x 60 EXAMPLE If you collect 5 gal of water and the pump takes 40 seconds to complete a c...

Page 4: ...m but it is recommended that you check your local plumbing codes Copper and PVC CPVC and PEX are the most popular The system has 3 connections an inlet an outlet and a drain line connection If you are...

Page 5: ...nto the open end of the bypass valve and lock them in by inserting the red locking clips into the slots Fig 5 For ease of installation orient the inlet outlet fittings in the direction of the inlet ou...

Page 6: ...on all the way If you have no leaks proceed to the next steps Connect the control valve to the AC power source Fig 9 Manually put the CAFO filter into the BACKWASH cycle by pressing the REGEN button s...

Page 7: ...ve Mode 11 Valve ID The control valve has a display screen and 4 buttons PROGRAMMING I LANGUAGE SELECTION SETTINGS The function of this key is to enter the level one programming mode where the valve s...

Page 8: ...nt minutes TIME OF DAY 08 51 PM TIME OF DAY 08 51 PM 7 Press SETTINGS key again and AM PM will be highlighted 8 Now press UP or DOWN key to change AM PM value to current time 9 Press SETTINGS button a...

Page 9: ...is setting unless you want to change all your settings to factory settings PROGRAMMING COMPLETE 18 Press SETTINGS again and this completes the programming Unlock display by pressing SETTINGS for 3 sec...

Page 10: ...s valve located at the back of the control see Fig 3 To resume filtered water service open bypass valve by rotating the knobs counterclockwise G MAINTENANCE The CAFO948 filter does not require any rou...

Page 11: ...e 6 Supply water pH too low 1 Plug in control valve to power supply 2 Open bypass valve 3 Check if riser is cracked or O ring is damaged Replace faulty parts 4 Replace valve seals spacer and piston as...

Page 12: ...12 I PARTS LIST Valve body Power head...

Page 13: ...13 To order replacement parts Call 1800 667 8072 Monday to Friday 8 00 AM to 5 PM EST...

Page 14: ...m the Warrantor This warranty does NOT cover and is intended to exclude any liability on the part of Envirogard for any incidental damages consequential damages labour charges or any other costs incur...